September 2016
Part No. 1272852
GTH-5519
4-13
Section 4 Fault Codes
SPN
FMI Short Text Detail
91
8
Accelerator pedal dutycycle PWM signal; signal range check low
91
8
Acceleration pedal cycle duration PWM signal; signal range check low
91
4
Sensor error accelerator pedal; signal range check low
29
4
Sensor error handthrottle sensor; signal range check low
523921
3
Sensor error burner temperature; signal range check high
3532
3
Sensor error urea tank level; signal range check high
523921
4
Sensor error burner temperature; signal range check low
3532
4
Sensor error urea tank level; signal range check low
1079
13
Sensor supply voltage monitor 1 error (ECU)
1080
13
Sensor supply voltage monitor 2 error (ECU)
523601
13
Sensor supply voltage monitor 3 error (ECU)
677
3
Starter relay high side; short circuit to battery
677
4
Starter relay high side; short circuit to ground
677
5
Starter relay; no load error
677
12
Starter relay; powerstage over temperature
677
3
Starter relay low side; short circuit to battery
677
4
Starter relay low side; short circuit to ground
523922
5
Burner shut off valve; open load
523922
3
Burner shut of valve; short circuit to battery
523922
4
Burner shut of valve; short circuit to ground
624
5
SVS lamp; open load
624
12
SVS lamp; powerstage over temperature
624
3
SVS lamp; short circuit to battery
624
4
SVS lamp; short circuit to ground
523612
14
Softwarereset CPU SWReset_0
523612
14
Softwarereset CPU SWReset_1
523612
14
Softwarereset CPU SWReset_2
91
11
Plausibility error between APP1 and APP2 or APP1 and idle switch
523550
12
T50 start switch active for too long
172
3
Sensor error intake air; signal range check high
172
4
Sensor error intake air sensor; signal range check low
172
2
Intake air sensor; plausibility error
523921
11
Sensor burner temperature; plausibility error
523921
0
Physical range check high for burner temperature