September 2016
Part No. 1272852
GTH-5519
4-19
Section 4 Fault Codes
SPN
FMI Short Text Detail
524045
9
Master-Slave CAN; Message-Counter-Error of CAN-Receive-Frame ComMSMoFOvR
524046
9
Master-Slave CAN; Checksum-Error of CAN-Receive-Frame ComMSMoFOvR
524047
9
Master-Slave CAN; Messsage-Length-Error of CAN-Receive-Frame ComMSMoFOvR
524048
9
Timeout error CAN message ComMSMoFOvR1TO error memory Slave
524049
9
Message copy error in the Master / Slave data transfer
523788
0
CAN-Transmit-Frame ComTrbChActr "BusOff-Satus"; Wastegate
523788
0
CAN-Transmit-Frame ComTrbChActr disable error; wastegate
523788
0
CAN-Transmit-Frame ComTrbChActr plausibility error; wastegate
523788
0
Timeout Error of CAN-Transmit-Frame ComTrbChActr; Wastegate
524024
11
Deviation of the exhaust gas temperature setpoint to actual value downstream (DOC) too high
523995
13
check of missing injector adjustment value programming (IMA) injector 7 (in firing order)
523996
13
check of missing injector adjustment value programming (IMA) injector 8 (in firing order)
523998
4
Injector cylinder bank 2 slave; short circuit
523999
12
Injector powerstage output Slave defect
524000
5
Injector 7 (in firing order); interruption of electric connection
524001
5
Injector 8 (in firing order); interruption of electric connection
524000
3
Injector 7 (in firing order); short circuit
524001
3
Injector 8 (in firing order); short circuit
524000
4
High side to low side short circuit in the injector 7 (in firing order)
524001
4
High side to low side short circuit in the injector 8 (in firing order)
2797
4
Injector diagnostics; timeout error of short circuit to ground measurement cyl. Bank 0
2798
4
Injector diagnostics; timeout error of short circuit to ground measurement cyl. Bank 1
2798
4
Injector diagnostics; short circuit to ground monitoring Test in Cyl. Bank 0
2798
4
Injector diagnostics; short circuit to ground monitoring Test in Cyl. Bank 1
524035
12
Injector diagnostics; time out error in the SPI communication
524036
12
Injector diagnostics Slave; time out error in the SPI communication
524004
12
Too many recognized misfires in cylinder 7 (in firing order)
524005
12
Too many recognized misfires in cylinder 8 (in firing order)
524069
9
Timeout Error of CAN-Receive-Frame MSMon_FidFCCTO; Master-Slave CAN communication faulty
524052
11
Error memory Slave reports FID MSMonFC2; Shut-Off Path test error of fuel injection system
524052
11
Error memory Slave reports FID MSMonFC3; timeout of engine state messages (ComMS_Sys1 7) from master ECU
523919
2
Sensor air pump airpressure; plausibility error
523920
2
Sensor exhaust gas back pressure burner; plausibility error
3253
2
Sensor differential pressure (DPF); plausibility error
FAULT CODES