4-24
GTH-5519
Part No. 1272852
September 2016
Section 4 • Fault Codes
SPN
FMI Short Text Detail
97
3
Sensor error water in fuel; signal range check high
97
4
Sensor error water in fuel; signal range check low
97
12
Water in fuel level prefilter; maximum value exceeded
100
0
High oil pressure; warning threshold exceeded
100
0
High oil pressure; shut off threshold exceeded
100
1
Low oil pressure; warning threshold exceeded
100
1
Low oil pressure; shut off threshold exceeded
100
3
Sensor error oil pressure; signal range check high
100
4
Sensor error oil pressure sensor; signal range check low
102
2
Charged air pressure above warning threshold
102
2
Charged air pressure above shut off threshold
102
3
Sensor error charged air pressure; signal range check high
102
4
Sensor error charged air pressure; signal range check low
105
0
High charged air cooler temperature; warning threshold exceeded
105
0
High charged air cooler temperature; shut off threshold exceeded
105
3
Sensor error charged air temperature; signal range check high
105
4
Sensor error charged air temperature; signal range check low
107
0
High air filter differential pressure; warning threshold exceeded
107
3
Sensor error airfilter differential pressure; short circuit to battery
107
4
Sensor error airfilter differential pressure; short circuit to ground
108
3
Sensor error ambient air pressure; signal range check high
108
4
Sensor error ambient air pressure; signal range check low
110
0
High coolant temperature; warning threshold exceeded
110
0
High coolant temperature; shut off threshold exceeded
110
3
Sensor error coolant temperature; signal range check high
110
4
Sensor error coolant temperature; signal range check low
111
1
Coolant level too low
132
11
Air flow sensor load correction factor exceeding the maximum drift limit; plausibility error
132
11
Air flow sensor load correction factor exceeding drift limit; plausibility error
132
11
Air flow sensor low idle correction factor exceeding the maximum drift limit
132
11
Air flow sensor load correction factor exceeding the maximum drift limit
157
3
Sesnor error rail pressure; signal range check high
157
4
Sensor error rail pressure; signal range check low
164
2
Rail pressure safety function is not executed correctly