4-26
GTH-5519
Part No. 1272852
September 2016
Section 4 • Fault Codes
SPN
FMI Short Text Detail
190
14
Engine speed above warning threshold (Overrun Mode)
190
14
Camshaft-and Crankshaft speed sensor signal not available on CAN
411
0
Physical range check high for differential pressure Venturiunit (EGR)
411
1
Physical range check low for differential pressure Venturiunit (EGR)
411
3
Sensor error differential pressure Venturiunit (EGR); signal range check high
411
4
Physical range check low for EGR differential pressure
411
4
Sensor error differential pressure Venturiunit (EGR); signal range check low
412
3
Sensor error EGR cooler downstream temperature; signal range check high
412
4
Sensor error EGR cooler downstream temperature; signal range check low
520
9
Timeout Error of CAN-Receive-Frame TSC1TR; Setpoint
597
2
Break lever mainswitch and break lever redundancyswitch status not plausible
624
3
SVS lamp; short circuit to battery
624
4
SVS lamp; short circuit to ground
624
5
SVS lamp; open load
624
12
SVS lamp; powerstage over temperature
630
12
Access error EEPROM memory (delete)
630
12
Access error EEPROM memory (read)
630
12
Access error EEPROM memory (write)
639
14
CAN-Bus 0 "BusOff-Status"
651
3
Injector 1 (in firing order); short circuit
651
4
High side to low side short circuit in the injector 1 (in firing order)
651
5
Injector 1 (in firing order); interruption of electric connection
652
3
Injector 2 (in firing order); short circuit
652
4
High side to low side short circuit in the injector 2 (in firing order)
652
5
Injector 2 (in firing order); interruption of electric connection
653
3
Injector 3 (in firing order); short circuit
653
4
High side to low side short circuit in the injector 3 (in firing order)
653
5
Injector 3 (in firing order); interruption of electric connection
654
3
Injector 4 (in firing order); short circuit
654
4
High side to low side short circuit in the injector 4 (in firing order)
654
5
Injector 4 (in firing order); interruption of electric connection
655
3
Injector 5 (in firing order); short circuit
655
4
High side to low side short circuit in the injector 5 (in firing order)
655
5
Injector 5 (in firing order); interruption of electric connection
FAULT CODES