September 2016
Part No. 1272852
GTH-5519
4-27
Section 4 Fault Codes
SPN
FMI Short Text Detail
656
3
Injector 6 (in firing order); short circuit
656
4
High side to low side short circuit in the injector 6 (in firing order)
656
5
Injector 6 (in firing order); interruption of electric connection
676
11
Cold start aid relay error.
676
11
Cold start aid relay open load
677
3
Starter relay high side; short circuit to battery
677
3
Starter relay low side; short circuit to battery
677
4
Starter relay high side; short circuit to ground
677
4
Starter relay low side; short circuit to ground
677
5
Starter relay; no load error
677
12
Starter relay; powerstage over temperature
703
3
Engine running lamp; short circuit to battery
703
4
Engine running lamp; short circuit to ground
703
5
Engine running lamp; open load
703
12
Engine running lamp; powerstage over temperature
729
5
Cold start aid relay open load
729
12
Cold start aid relay; over temperature error
898
9
Timeout Error of CAN-Receive-Frame TSC1TE; Setpoint
975
3
Digital fan control; short circuit to battery
975
3
Fan actuator (PWM output); short circuit to battery
975
4
Digital fan control; short circuit to ground
975
4
Fan actuator (PWM output); short circuit to ground
975
5
Digital fan control; open load
975
5
Fan actuator (PWM output); open load
975
12
Digital fan control; powerstage over temperature
975
12
Fan actuator (PWM output); powerstage over temperature
1079
13
Sensor supply voltage monitor 1 error (ECU)
1080
13
Sensor supply voltage monitor 2 error (ECU)
1109
2
Engine shut off demand ignored
1136
0
Physikal range check high for ECU temperature
1136
1
Physikal range check low for ECU temperature
1136
3
Sensor error ECU temperature; signal range check high
1136
4
Sensor error ECU temperature; signal range check low
1176
3
Sensor error pressure sensor upstream turbine; signal range check high