Pre-operation Inspection
o
Be sure that the operator's, safety and
responsibilities manuals are complete, legible
and in the storage container located on the
mast.
o
Be sure that all decals are legible and in place.
See Decals section.
o
AC & DC models: Check for hydraulic oil leaks
and proper oil level. Add oil if needed. See
Maintenance section.
o
DC models: Check for battery fluid leaks and
proper fluid level. Add distilled water if needed.
See Maintenance section.
Check the following components or areas for
damage, modifications and improperly installed or
missing parts:
o
Electrical components, wiring and
electrical cables
o
Hydraulic power unit, hoses, fittings and
cylinders
o
Hydraulic manifolds and foot pump
o
Platform entry mid-rail or gate
o
Sequencing cables and pulleys
o
Lifting chains and idler wheels
o
Mast columns and counterweight
o
Nuts, bolts and other fasteners
o
Breather cap
o
Foot pads
o
Adjustable glide pads
If equipped: Power wheel assist option
o
Steer handle
o
Hydraulic motor and hoses
If equipped: IWP-20S with Outreach option
o
Locking bracket
o
Handle and handle lock
o
Extension arms
o
Confirm proper counterweight
configuration (part number is stamped on
top of counterweight)
ANSI & CE Indoor
Front P/N
Rear P/N
IWP-20S Standard Base
37354
37355
IWP-20S Wide Base
40990
40991
CSA
Front P/N
Rear P/N
IWP-20S Wide Base
40988
40989
Check entire machine for:
o
Dents or damage
o
Corrosion or oxidation
o
Cracks in welds or structural components
o
Inspect and clean battery terminals and all
battery cable connections
o
Be sure that all structural and other critical
components are present and all associated
fasteners and pins are in place and properly
tightened.