Part No. 62756
Genie S-120 & Genie S-125
17
Operator's Manual
First Edition · Fourth Printing
FUNCTION TESTS
Test the Tilt Sensor
19 Push one of the LCD
screen buttons until
TURNTABLE LEVEL
SENSOR X-DIRECTION
appears.
Result: The LCD screen should display the
angle in degrees.
20 Push one of the LCD screen buttons until
TURNTABLE LEVEL SENSOR Y-DIRECTION
appears.
Result: The LCD screen should display the
angle in degrees.
21 Push one of the LCD screen buttons until
PLATFORM LEVEL SENSOR DEGREES
appears.
Result: The LCD screen should display the
angle in degrees.
Test the Operating Envelope
22 Simultaneously push the
LCD screen buttons shown
to activate status mode.
23 Push one of the LCD screen
buttons shown until BOOM
ANGLE is displayed.
24 Raise the boom and observe the LCD screen.
Result: The LCD screen should display:
< 10
>= 10
>= 50
> 65
25 Push one of the LCD screen buttons shown until
BOOM LENGTH is displayed.
26 Extend the boom and observe the LCD screen.
Result: The LCD screen should display:
at 0
> 0
> 80
= 100
> 100
27 Retract the boom.
At the Platform Controls
Test Emergency Stop
28 Turn the key switch to platform control.
29 Push in the platform red Emergency Stop button
to the
OFF
position.
Result: The engine should turn off and no
functions should operate.
30 Pull out the red Emergency Stop button and
restart the engine.
Test the Hydraulic Oil Return Filter
31 Press the engine idle speed select button until
the indicator light next to high idle (rabbit
symbol) is on.
32 Locate and check the
hydraulic filter
condition indicator.
Result: The filter
should be operating
with the plunger in
the green area.
33 Press the engine idle speed select button until
the indicator light next to foot switch activated
high idle (rabbit and foot switch symbol) is on.