ID Component ID Name
Cause
Effect
Solution
40 Jib Select
Coil
11 Shorted
to supply
voltage
PCON detected
V18PRR is short to
supply
Jib and platform
functions will not
operate
*With a voltmeter, measure Y18.
Proper resistance should be
between 5 - 60 ohms. Replace Y18 if
resistance is outside of those values.
*Verify wiring for V18PRR (GR/BK,
PCON J12-4) and check for short
circuits.
41 Turntable
Rotate
Joystick
11 Shorted
to supply
voltage
Circuit C165TTR is
above 4.5 V.
Turntable Rotate
functions will not
operate.
* Leave joystick in neutral position
and cycle power.
* If fault persists, with a voltmeter
check that C165TTR (WH/RD,
PCON J18-2) is at 2. 5V +/- 0.2 V at
startup and does not go above 4.5 V
or below 0.5 V when fully stroked in
each direction.
* Replace joystick if voltage check
fails.
27 Active at
startup
Circuit C165TTR
voltage was not
within the startup
voltage range of
2.5 V +/- 0.2 V.
42 Turntable
Rotate CW
Coil
11 Shorted
to supply
voltage
TCON detected
that C4TRL circuit
is shorted to 12 V
or GND.
Turntable Rotate
functions will not
operate.
* With a voltmeter, measure Y24.
Proper resistance should be
between 5 - 60 ohms. Replace Y24 if
resistance is outside of those values.
* Verify wiring for C4TRL (WH,
TCON J3-12) and check for open or
short circuits.
43 Turntable
Rotate CCW
Coil
11 Shorted
to supply
voltage
TCON detected
that C5TRR circuit
is shorted to 12 V
or GND.
Turntable Rotate
functions will not
operate.
* With a voltmeter, measure Y23.
Proper resistance should be
between 5 - 60 ohms. Replace Y23 if
resistance is outside of those values.
* Verify wiring for C5TRR (WH/BK,
TCON J3-1) and check for open or
short circuits.
44 Drive Enable
Toggle
Switch
27 Active at
startup
Toggle switch input
was detected as
HIGH at start-up.
Drive Enable switch
will not operate,
possibly preventing
drive while the
turntable is rotated.
*Verify with a voltmeter that the Drive
Enable Toggle Switch (TS15) is
operating properly.
* C143DEL (BL/RD, PCON J16-7)
should be 0 V with the switch OFF
and 12 V with the switch held in the
ON position.
*Cycle power to allow the machine to
re-test the fault.
Summary of Contents for S-40 TRAX
Page 144: ...Service and Repair Manual July 2019 134 Electrical Schematic TCON ...
Page 147: ...July 2019 Service and Repair Manual 137 Electrical Schematic PCON ...
Page 148: ...Service and Repair Manual July 2019 138 Electrical Schematic Deutz 2 9 Models ...
Page 150: ...Service and Repair Manual July 2019 140 S 40 XC S 45 XC S 40 TraX S 45 TraX Part No 1286829GT ...
Page 152: ...Service and Repair Manual July 2019 142 Electrical Schematic Deutz 2011 Models ...
Page 153: ...July 2019 Service and Repair Manual 143 Electrical Schematic Perkins 404F Models ...
Page 156: ...Service and Repair Manual July 2019 146 Electrical Schematics Ford MSG425 Models ...
Page 159: ......