Part No. 147753
S-60 • S-65 • S-60 TRAX • S-65 TRAX
4 - 5
S-60 HC • S-60X • S-60XC
December 2013
Section 4 • Repair Procedures
PLATFORM CONTROLS
How to Adjust the Joystick
Max-out Setting
The max-out setting of a joystick controls the
maximum speed of a joystick-controlled machine
function. Whenever a hydraulic cylinder, drive
motor or hydraulic pump is replaced, the max-out
setting should be adjusted to maintain optimum
performance. The max-out settings on the joystick
can be changed to compensate for hydraulic pump
wear to maintain peak performance from the
machine.
Note: Perform this procedure on a firm, level
surface.
1 Pull out the red Emergency Stop button to the
on position at the ground controls.
2 Turn the key switch to platform control. Do not
start the engine.
3 Push in the platform controls red Emergency
Stop button to the off position.
4 Do not press down the foot switch.
5 Move and hold the drive enable toggle switch in
the right position and pull out the red
Emergency Stop button to the on position.
6 When the alarm sounds, release the drive
enable toggle switch.
7 Momentarily activate the drive enable toggle
switch in the right direction 4 times.
Result: There should be a pause and the alarm
should sound 4 times indicating that the
machine is in max-out calibration mode.
Result: The alarm does not sound. Repeat steps
3 through 7.
8 Start the engine from the platform controls and
press down the foot switch.
9 Start a timer and activate the machine function
that needs to be adjusted. Record the time it
takes for that function to complete a full cycle
(ie; boom up).
10 Compare the machine function time with the
function times listed in Section 2,
Specifications.
Determine whether the function
time needs to increase or decrease.
11 While the joystick is activated, adjust the max-
out setting to achieve the proper function cycle
time. Momentarily move the drive enable toggle
switch in the right direction to increase the
function speed or momentarily move the drive
enable toggle switch in the left direction to
decrease the function speed.
Note: Each time the drive enable toggle switch is
momentarily moved, the function speed will change
in 2% increments from a default of 100%, with a
minimum of 60% and a maximum of 120%.
Summary of Contents for S-60 HC
Page 1: ......
Page 215: ...Section 6 Schematics December2013 6 7 Ford DSG 423 Engine Wire Harness 6 8 ...
Page 218: ...December2013 Section 6 Schematics 6 10 Ford MSG 425 Engine Wire Harness 6 9 ...
Page 219: ...Section 6 Schematics December2013 6 11 Electrical Schematic Options All Models 6 12 ...
Page 222: ...December2013 Section 6 Schematics 6 14 Wiring Diagram Belt Driven Generator 6 13 ...
Page 223: ...Section 6 Schematics December2013 6 15 Wiring Diagram 3kW Hydraulic Generator 6 16 ...
Page 234: ...December2013 Section 6 Schematics 6 26 Hydraulic Schematic 2WD Models after SN 21396 6 25 ...
Page 238: ...December2013 Section 6 Schematics 6 30 Hydraulic Schematic 4WD Models after SN 21396 6 29 ...
Page 365: ...Section 6 Schematics December2013 6 157 Electrical Schematic S 60 HC CE 6 158 ...
Page 368: ...December2013 Section 6 Schematics 6 160 Chassis Wiring Diagram S 60 HC CE 6 159 ...
Page 373: ...Section 6 Schematics December2013 6 165 Platform Control Box Wiring Diagram S 60 HC CE 6 166 ...
Page 461: ......