3 - 44
S-60 • S-65 • S-60 TRAX • S-65 TRAX
Part No. 147753
S-60 HC • S-60X • S-60XC
December 2013
Section 3 • Scheduled Maintenance Procedures
3 Determine the maximum platform capacity.
Refer to the machine serial plate.
4 Using a suitable lifting device, place a test
weight equal to that of the available capacity in
one of the locations shown.
Refer to Illustration 1.
Result: The platform overload indicator lights
should be off at both the ground and platform
controls and the alarm should not sound.
Result: The platform overload indicator lights are
on and the alarm is sounding. Calibrate the
platform overload system. Refer to Repair
Procedure 2-3,
How to Calibrate the Platform
Overload System (if equipped), S-60, S-65,
S-60 TRAX and S-65 TRAX.
5 Carefully move the test weight to each
remaining location. Refer to Illustration 1.
Result: The platform overload indicator lights
should be off at both the ground and platform
controls and the alarm should not sound.
Result: The platform overload indicator lights are
on and the alarm is sounding. Calibrate the
platform overload system. Refer to Repair
Procedure 2-3,
How to Calibrate the Platform
Overload System (if equipped), S-60, S-65,
S-60 TRAX and S-65 TRAX.
Illustration 1
6 Using a suitable lifting device, place an
additional 50 lbs / 23 kg of weight onto the
platform.
Result: The alarm should sound.
The platform overload indicator lights should be
flashing at both the ground and platform
controls.
Result: The alarm does not sound and the
platform overload indicator lights are not
flashing. Calibrate the platform overload
system. Refer to Repair Procedure 2-3,
How to Calibrate the Platform Overload System
(if equipped), S-60, S-65, S-60 TRAX and
S-65 TRAX.
Note: There may be a 2 second delay before the
overload indicator lights flash and the alarm
sounds.
7 Carefully move the test weights to each
remaining location on the platform.
Refer to Illustration 1.
Result: The alarm should sound.
The platform overload indicator lights should be
flashing at both the ground and platform
controls.
Result: The alarm does not sound and the
platform overload indicator lights are not
flashing. Calibrate the platform overload
system. Refer to Repair Procedure 2-3,
How to Calibrate the Platform Overload System
(if equipped), S-60, S-65, S-60 TRAX and
S-65 TRAX.
Note: There may be a 2 second delay before the
overload indicator lights flash and the alarm
sounds.
CHECKLIST
C
PROCEDURES
Summary of Contents for S-60 HC
Page 1: ......
Page 215: ...Section 6 Schematics December2013 6 7 Ford DSG 423 Engine Wire Harness 6 8 ...
Page 218: ...December2013 Section 6 Schematics 6 10 Ford MSG 425 Engine Wire Harness 6 9 ...
Page 219: ...Section 6 Schematics December2013 6 11 Electrical Schematic Options All Models 6 12 ...
Page 222: ...December2013 Section 6 Schematics 6 14 Wiring Diagram Belt Driven Generator 6 13 ...
Page 223: ...Section 6 Schematics December2013 6 15 Wiring Diagram 3kW Hydraulic Generator 6 16 ...
Page 234: ...December2013 Section 6 Schematics 6 26 Hydraulic Schematic 2WD Models after SN 21396 6 25 ...
Page 238: ...December2013 Section 6 Schematics 6 30 Hydraulic Schematic 4WD Models after SN 21396 6 29 ...
Page 365: ...Section 6 Schematics December2013 6 157 Electrical Schematic S 60 HC CE 6 158 ...
Page 368: ...December2013 Section 6 Schematics 6 160 Chassis Wiring Diagram S 60 HC CE 6 159 ...
Page 373: ...Section 6 Schematics December2013 6 165 Platform Control Box Wiring Diagram S 60 HC CE 6 166 ...
Page 461: ......