Second Edition • First Printing
Operator's Manual
Work Area Safety
Part No. 1261735
S-60X 19
Welder Safety
Read, understand and obey all warnings and
instructions provided with the welding power unit.
Do not connect weld leads or cables unless the
welding power unit is turned off at the platform
controls.
Do not operate unless the weld cables are properly
connected and the welder is properly grounded.
The weight of the welder will reduce the rated
platform capacity and must be factored into the
total platform load. The welder power supply
weighs 75 lbs / 34 kg.
Do not operate the welder unless a fire
extinguisher is immediately available for instant
use, per OSHA regulation 1926.352(d).
Weld Line to Platform Safety
Read, understand and obey all warnings and
instructions provided with the welding power unit.
Do not connect weld leads or cables unless the
welding power unit is turned off at the platform
controls.
Do not operate unless the weld cables are properly
connected.
Connect the positive lead to the twist-lock
connector at the turntable and platform.
Clamp the negative lead to the ground post at the
turntable and platform.
Pipe Cradle Safety
Read, understand and obey all warnings and
instructions provided with the pipe cradles.
Do not exceed the rated platform capacity. The
pipe cradle assembly and the weight in the pipe
cradles will reduce rated platform capacity and
must be factored into total platform load.
The pipe cradle assembly weighs 21 lbs / 9.5 kg.
The maximum capacity of the pipe cradle
assembly is 200 lbs / 91 kg.
The weight of the pipe cradle assembly and the
load in the pipe cradles may limit the maximum
number of occupants in platform.
Center the load within the perimeter of the
platform.
Secure the load to the platform.
Do not obstruct the entrance or the exit of the
platform.
Do not obstruct the ability to operate the platform
controls or the red Emergency Stop button.
Do not operate unless you are adequately
instructed and are aware of all of the hazards
associated with movement of the platform with an
overhanging load.
Do not cause a horizontal force or side load to
machine by raising or lowering a fixed or
overhanging load.
Electrocution Hazard:
Keep pipes away from all
energized electrical conductors.
Summary of Contents for S-60X