Second Edition • First Printing
Operator's Manual
Operating
Instructions
Part No. 1261735
S-60X 45
Starting the Engine
Gasoline/LPG models
1
At the ground controls, turn the key switch to
the desired position.
2
Be sure both ground and platform control red
Emergency Stop buttons are pulled out to the
on position.
3
Choose fuel by moving the fuel select switch to
the desired position.
4
Move the engine start toggle switch to either
side. If the engine fails to start or dies, the
restart delay will disable the start switch for
3 seconds.
Diesel models
1
At the ground controls, turn the key switch to
the desired position.
2
Be sure both ground and platform control red
Emergency Stop buttons are pulled out to the
on position.
Models with glow plug toggle switch:
3
Move the glow plug switch to either side and
hold for 3 to 5 seconds.
4
Move the engine start toggle switch to either
side. If the engine fails to start or dies, the
restart delay will disable the start switch for
3 seconds.
Models with automatic glow plugs:
5
The LCD screen will display the glow
plug symbol when the automatic glow
plugs are on.
6
When the automatic glow plug symbol turns off,
move the engine start toggle switch to either
side. If the engine fails to start or dies, the
restart delay will disable the start switch for
3 seconds.
Summary of Contents for S-60X
Page 69: ......