Service and Repair Manual
October 2016
Platform Components
30
S-80 • S-85 • S-80X
Part No. 1269074
5
Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to
2 inches. Allow the platform to settle.
Result: The overload indicator lights are off
and the alarm does not sound. Proceed to step
6.
Result: The overload indicator lights are
flashing at the platform and ground controls,
and the alarm is sounding. Slowly tighten the
load spring adjustment nut in a clockwise
direction in 10° increments until the overload
indicator light turns off, and the alarm does not
sound. Proceed to step 8.
Note: The platform will need to be moved up and
down and allowed to settle between each
adjustment.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
6
Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to
2 inches. Allow the platform to settle.
Result: The overload indicator lights are off at
the platform and ground controls, and the
alarm does not sound. Slowly loosen the load
spring adjustment nut in a counterclockwise
direction in 10° increments until the overload
indicator light flashes at both the platform and
ground controls, and the alarm sounds.
Proceed to step 7.
Result: The overload indicator lights are
flashing at the platform and ground controls,
and the alarm is sounding. Repeat this
procedure beginning with step 5.
Note: The platform will need to be moved up and
down and allowed to settle between each
adjustment.
Note: There may be a 2 second delay before the
platform overload indicator lights and alarm
responds.
7
Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to
2 inches. Allow the platform to settle.
Result: The overload indicator lights are off
and the alarm does not sound. Proceed to step
8.
Result: The overload indicator lights are
flashing at the platform and ground controls,
and the alarm is sounding. Repeat this
procedure beginning with step 5.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
8
Add an additional 10 lb / 4.5 kg test weight to
the platform.
Result: The overload indicator light is flashing
at both the ground and platform controls, and
the alarm is sounding. Proceed to step 9.
Result: The overload indicator light is off at
both the ground and platform controls, and the
alarm does not sound. Remove the additional
10 lb / 4.5 kg test weight. Repeat this
procedure beginning with step 6.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
Summary of Contents for S-80
Page 16: ......
Page 76: ...Service and Repair Manual October 2016 Manifolds 60 S 80 S 85 S 80X Part No 1269074 ...
Page 86: ...Service and Repair Manual October 2016 Manifolds 70 S 80 S 85 S 80X Part No 1269074 ...
Page 144: ...Service and Repair Manual October 2016 128 Continental TME27 Engine Harness ...
Page 147: ...October 2016 Service and Repair Manual 131 S 80X Ground Control Box Wiring Diagram ...
Page 148: ...Service and Repair Manual October 2016 132 Deutz TD2 9 L4 Engine Harness ...
Page 151: ...October 2016 Service and Repair Manual 135 Perkins 404F 22T Engine Harness ...
Page 289: ...October 2016 Service and Repair Manual 273 Continental Options Schematic ...
Page 292: ...Service and Repair Manual October 2016 276 Deutz and Perkins Options Schematic ...
Page 293: ...October 2016 Service and Repair Manual 277 Platform Level Cutout CTE Option ...
Page 296: ...Service and Repair Manual October 2016 280 12 kW Hydraulic Generator Wiring Diagram ...
Page 297: ...October 2016 Service and Repair Manual 281 12 kW Hydraulic Generator Electrical Schematic ...
Page 300: ...Service and Repair Manual October 2016 284 Belt Driven Generator Option ...
Page 301: ...October 2016 Service and Repair Manual 285 Hydraulic Schematic 2WD Models ...
Page 305: ......