background image

Quick Start Guide

2 Channel Wiegand Radio Receiver - Up to 30m

6

1.11 6-Pin Terminal Block

Refer to the information below for cabling to the Receiver:
AD0: Button One, Wiegand Data 0, Channel A.
AD1: Button One, Wiegand Data 1, Channel A.
BD0: Button Two, Wiegand Data 0, Channel B.
BD1: Button Two, Wiegand Data 1, Channel B.
GND: Power, 0VDC
+VDC: Power, 12VDC Nominal.

NOTE: Apply positive voltage only to the +VDC Pin on the Terminal Block.

1.12 Connection

Connection must be done in accordance with NFPA 70. Do not connect to a receptacle 
controlled by a switch. Connect to a power limited DC voltage source.

1.13 Troubleshooting

No data received/Transmitter not enrolled
Transmitter must be clicked twice to be learned by the Receiver upon initial Receiver 
power up

Summary of Contents for WRR-2

Page 1: ...Quick Start Guide Please read these instructions carefully before operating the unit and keep for further reference 2 Channel Wiegand Radio Receiver Up to 30m WRR 2 ...

Page 2: ...nced installing technicians It is a basic reference to ensure all connections are properly made Installation and wiring of systems must be in accordance with the National Electrical Code ANSI NFPA 70 The contents of this manual are subject to change without notice ...

Page 3: ...Product Layout 4 1 3 Specification 4 1 4 Cable Requirements 5 1 5 Output Formats 5 1 6 Grounding 5 1 7 Power 5 1 8 Mounting 5 1 9 Read Range 5 1 10 External LED Indicator 5 1 11 6 Pin Terminal Block 6 1 12 Connection 6 1 13 Troubleshooting 6 ...

Page 4: ...cs sealed in a weather resistant enclosure IP65 1 2 Product Layout a 6 PIN Terminal Block 1 3 Specification Frequency 433MHz Transmission Rolling code and encryption IP Rating IP65 Voltage DC12V Nominal Current Draw 80mA typical DC12V Read Range Up to 30m Installer adjustable Cabling 24 AWG minimum multi conductor stranded with an overall foil shield Interface Wiegand 26 Bit industry standard and ...

Page 5: ...ended for best operation 1 8 Mounting The Receiver may be mounted indoors or outdoors The enclosure includes pre drilled holes in the four corners allowing mounting to a flat surface Use supplied 6 mounting screws or equivalent security screws for installation 1 9 Read Range Read range is nominally up to 100 feet 30 5 m For optimal read range it is important that the Receiver be mounted as far fro...

Page 6: ...D1 Button Two Wiegand Data 1 Channel B GND Power 0VDC VDC Power 12VDC Nominal NOTE Apply positive voltage only to the VDC Pin on the Terminal Block 1 12 Connection Connection must be done in accordance with NFPA 70 Do not connect to a receptacle controlled by a switch Connect to a power limited DC voltage source 1 13 Troubleshooting No data received Transmitter not enrolled Transmitter must be cli...

Page 7: ...Sales 44 0 1707 330541 Enquiries sales genieproducts co uk Website www genieproducts co uk ...

Reviews: