Part No. 29487
Genie Z-45/22
5 - 45
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
wedges
extend
3
inches
wedges do not
extend 3 inches
0V
12V
0V
12V
Raise the primary boom
until it is above the drive
limit switch and measure
the oscillate lock-out
wedges. See
Maintenance Procedures
B-17.
Oscillate
Lock-out
Function
Inoperative
12V
0V
Check voltage at blk #57
wire on CR7.
Open in wht wire (12V
supply) to oscillate
limit switches OR one
or both oscillate limit
switches is defective.
Check CR7 green
grounding wire OR
replace CR7 relay or
socket.
Drive limit switch
shorted, repair or
replace.
Check voltage at blk #56
on CR6.
Replace CR6 relay or
relay socket.
Check voltage at blk #55
on oscillate valve.
Remove machine from
service and please
consult Genie Industries
service department.
Chart 30