Part No. 29487
Genie Z-45/22
5 - 53
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
0V
12V
12V
0V
0V
12V
low range operates
low range inoperative
low range inoperative
OK
bad
low range operates
OK
bad
Chart 36
Low Range
Drive Function
Inoperative
Be sure all other
functions operate
normally including
drive high range (two
wheel symbol).
Turn key switch to
platform controls, pull
both emergency stop
buttons on, switch drive
mode to low range (four
wheel symbol), press
down foot switch and
check voltage at red/wht
wire on drive mode
switch.
Replace drive mode
toggle switch.
Press down foot switch
and check voltage at
TB21.
Repair short in red/wht
wire circuit from drive
mode switch through
TP27 to TB21.
Press down foot switch
and check voltage at blk
#41 on traction bypass
valve (item Q).
Replace TR3 time delay
relay.
Interchange bypass
valve (item Q) with brake
release valve (item S).
Replace defective valve.
Interchange motor shift
valve (item R) with brake
release valve (item S).
Check drive mode toggle
switch. See Repair
section.
Replace toggle switch.
Replace defective valve.
Check drive resisters in
platform control box. See
repair section.
Possible defective drive
manifold or drive
manifold component.
Please consult Genie
Industries service
department.
Replace defective
resister(s).
Summary of Contents for Z-45/22
Page 1: ...Technical Publications First Edition Part No 29487 Service Manual Z 45 22 ...
Page 121: ...6 3 ...
Page 122: ......
Page 123: ...6 5 ...
Page 124: ...6 6 ...
Page 125: ...6 7 ...
Page 126: ...6 8 ...
Page 127: ......
Page 128: ...6 10 ...
Page 129: ...6 11 ...
Page 130: ...6 12 ...
Page 132: ...Z45 22 Hyd Index ...
Page 133: ...Z45 22 Hyd Index ...
Page 134: ...Z45 22 Hyd Index ...
Page 135: ...Z45 22 Hyd Index ...
Page 136: ...Z45 22 Hyd Index ...
Page 137: ...Z45 22 Hyd Index ...