Part No. 29487
Genie Z-45/22
4 - 19
Service Manual - First Edition
Section 4 - Scheduled Maintenance Procedures
B-19
Test the Service Horn
A functional service horn is essential to safe
machine operation. The service horn is activated
at the platform controls and sounds at the ground
as a warning to ground personnel. An improperly
functioning horn will prevent the operator from
alerting ground personnel of hazards or unsafe
conditions.
1 Turn the key switch to platform control and pull
out the Emergency Stop button to the
on
position.
2 Push down the service horn button at the
platform controls.
Result: The service horn should sound.
a
oscillate lock out wedge
2 Lower the primary boom onto its resting pad.
Result: The oscillate lock-out wedges should
fully retract.
When the primary and secondary
booms are fully lowered into the
stowed position and the engine is
turned off, the oscillate lock-out
wedges may partially extend. This
should not be mistaken for the full
lock-out position.
B-18
Test Platform Self-leveling
Precise automatic platform self-leveling throughout
the full cycle of boom raising and lowering is
essential for safe machine operation. The platform
is maintained at level by a hydraulic cylinder
(leveling slave cylinder) which is controlled by the
master cylinder located at the base of the primary
boom. A platform self-leveling failure creates an
unsafe working condition for platform and ground
personnel.
1 Start the engine from the ground controls, then
fully lower the boom into the stowed position.
2 Adjust the platform to a level position using the
manual platform leveling switch.
3 Raise and lower the primary boom through a
full cycle.
Result: The platform should remain level at all
times to within ±5 degrees.
B-20
Test the Foot Switch
A properly functioning foot switch is essential to
safe machine operation. Machine functions should
activate and operate smoothly as long as the foot
switch is pressed down, and promptly stop when
the foot switch is released. The foot switch will
also shift the engine into
high idle mode if the idle
select is switched to the rabbit and foot switch
symbol. An improperly functioning foot switch can
cause an unsafe working condition and endanger
platform and ground personnel.
The engine should not start if the
foot switch is pressed down.
1 Start the engine from the platform controls.
2 Without pressing down the foot switch, operate
the machine functions.
Result: The machine functions should not
operate.
3 Press down the foot switch and operate the
machine functions.
Result: The machine functions should operate.
3 inches
a
TABLE
B
PROCEDURES
Summary of Contents for Z-45/22
Page 1: ...Technical Publications First Edition Part No 29487 Service Manual Z 45 22 ...
Page 121: ...6 3 ...
Page 122: ......
Page 123: ...6 5 ...
Page 124: ...6 6 ...
Page 125: ...6 7 ...
Page 126: ...6 8 ...
Page 127: ......
Page 128: ...6 10 ...
Page 129: ...6 11 ...
Page 130: ...6 12 ...
Page 132: ...Z45 22 Hyd Index ...
Page 133: ...Z45 22 Hyd Index ...
Page 134: ...Z45 22 Hyd Index ...
Page 135: ...Z45 22 Hyd Index ...
Page 136: ...Z45 22 Hyd Index ...
Page 137: ...Z45 22 Hyd Index ...