Part No. 29487
Genie Z-45/22
5 - 25
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
4 to 5
ohms
0 or infinite ohms
2000 PSI
2000 PSI
2000 PSI
function
operates
function inoperative
less than 2000 PSI
less than 2000 PSI
less than 2000 PSI
CHART 16
Continued from the
previous page.
Hold toggle switch up
and manually override
directional valve (push in
button on end of valve
spool). Note: overriding
the valve will require two
people. If a helper is not
available, interchange
the valve (item C) with a
like valve (item B).
Check the resistance of
both directional valve
coils.
Replace the valve.
Replace the defective
valve coil(s).
Install a pressure gauge
at the quick disconnect
coupling on the function
manifold and hold the
function switch.
Check for mechanical
restriction keeping
secondary from
moving.
Remove and cap the up
function (steel) pressure
line attached to the
cylinder on the fuel tank
side. Then, with pressure
gauge still attached,
operate the function up.
Repair the cylinder
that was
disconnected.
Reconnect the cylinder.
Then disconnect up
function high pressure
hose and the fitting from
the engine side cylinder
and install into the other
cylinder in place of
plugged port. Remove
and cap the up function
(steel) pressure line
attached to the cylinder
on the engine side.
Then, with pressure
gauge still attached,
operate the function up.
Repair the cylinder
that was
disconnected.
Continued on the next
page.
Summary of Contents for Z-45/22
Page 1: ...Technical Publications First Edition Part No 29487 Service Manual Z 45 22 ...
Page 121: ...6 3 ...
Page 122: ......
Page 123: ...6 5 ...
Page 124: ...6 6 ...
Page 125: ...6 7 ...
Page 126: ...6 8 ...
Page 127: ......
Page 128: ...6 10 ...
Page 129: ...6 11 ...
Page 130: ...6 12 ...
Page 132: ...Z45 22 Hyd Index ...
Page 133: ...Z45 22 Hyd Index ...
Page 134: ...Z45 22 Hyd Index ...
Page 135: ...Z45 22 Hyd Index ...
Page 136: ...Z45 22 Hyd Index ...
Page 137: ...Z45 22 Hyd Index ...