5 - 32
Genie Z-45/22
Part No. 29487
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
less than 1200 PSI
1200 PSI
less than 1200 PSI
1200 PSI
Continued from the
previous page.
CHART 19
Interchange primary
relief valve (item T) with
like valve (item U). Hold
primary down function
and recheck pressure.
Replace defective valve.
Remove the primary
down high pressure line
from the manifold and
cap the port (P2). Hold
primary down function
and recheck pressure.
Repair the primary
function cylinder.
Internal defect in
manifold OR one of the
previous tests involving
the pump or manifold
components was
possibly overlooked or
diagnosed incorrectly.
Recheck and/or consult
Genie Industries service
department.