Part No. 75861
Genie Z-60/34
4 - 51
November 2003
Section 4 • Repair Procedures
REV A
How to Set Up the Directional
Valve Linkage
Adjustment of the directional valve
linkage is only necessary when
the linkage or valve has been
replaced.
1 Lower the boom to the stowed position.
2 Use a "bubble type" level to be sure the floor is
completely level.
Tip-over hazard. Failure to
perform this procedure on a level
floor could compromise the
stability of the machine resulting in
the machine tipping over.
3 Check the tire pressure in all four tires and add
air if needed to meet specification.
4 Remove the drive chassis cover and the non-
steer axle covers.
5 Place a "bubble type" level across the drive
chassis non-steer end. Check to be sure the
drive chassis is completely level.
6 To level the drive chassis, start the engine and
loosen the lock nuts on both sides of the
urethane cushions.
7 Push up or pull down on the threaded rod until
the machine is completely level.
8 Verify that the ground and drive chassis are
completely level.
9 Tighten the nuts on both sides of the urethane
cushions until they are snug. Tighten the
locknuts.
10 Check to be sure the drive chassis is
completely level.
11 Measure the distance between the drive
chassis and the non-steer axle on both sides
(from the inside of the drive chassis).
If the distance is not equal and the
adjustment to the linkage was
completed with the ground and
drive chassis level, repeat steps 6
through 10 OR consult Genie
Industries Service Department.
MANIFOLDS
Summary of Contents for Z-60/34
Page 12: ...Genie Z 60 34 Part No 75861 November 2003 This page intentionally left blank ...
Page 157: ......
Page 160: ...Electrical Schematic Deutz F4L 1011F Models November 2003 Section 6 Schematics ...
Page 162: ...Ground Control Box Wiring Diagram Deutz F4L 1011F Models November 2003 Section 6 Schematics ...
Page 164: ...Platform Control Box Wiring Diagram Deutz F4L 1011F Models November 2003 Section 6 Schematics ...
Page 165: ......
Page 168: ...Electrical Schematic Ford LRG 425 EFI Models November 2003 Section 6 Schematics ...
Page 170: ...Ground Control Box Wiring Diagram Ford LRG 425 EFI Models November 2003 Section 6 Schematics ...
Page 173: ...November2003 Section 6 Schematics PartNo 75861 GenieZ 60 34 6 11 ...
Page 176: ...Hydraulic Schematic 2WD Models before serial number 4461 November 2003 Section 6 Schematics ...
Page 178: ...Hydraulic Schematic 4WD Models before serial number 4461 November 2003 Section 6 Schematics ...
Page 180: ...Hydraulic Schematic 2WD Models after serial number 4460 November 2003 Section 6 Schematics ...
Page 182: ...Hydraulic Schematic 4WD Models after serial number 4460 November 2003 Section 6 Schematics ...