14
7.
Repeat steps 3 through 5 for all toggle catches.
8.
Push the locking levers of all toggle catches downwards until
the locking bolt engages by itself.
3.6
Removing the hazardous material
3.6.1
Safety instructions
If the transport container shows any signs of deposits, discoloration or a piercing smell, you
must assume that the electrolyte has leaked or there has been a thermal runaway in the bat-
tery.
Danger
Danger of poisoning due to toxic, partially odourless gases and toxic substances
Injuries ranging from severe to fatal
In the event of electrolyte leaking from the cell or battery, or a thermal runaway,
the transport container must be opened only by personnel wearing protective
equipment appropriate to the type of hazardous substance involved.
Danger
Danger of poisoning by inhalation of contaminated dust
Injuries ranging from severe to fatal
In the event of electrolyte leaking from the cell or battery, or a thermal runaway,
the transport container must be opened only by personnel wearing protective
equipment appropriate to the type of hazardous substance involved.
Warning
Risk of explosion due to explosive gases
Injuries ranging from severe to fatal
In the event that the cell or battery suffers a thermal runaway, avoid ignition
sources. If possible, provide sufficient ventilation.