- To avoid damaging the operator and/or interrupting operation of the
automated system, leave a distance of about 40 mm from the safety
mechanical stops.
- Make sure that at the end of both the opening and closing manoeuvre,
the relevant contact stays active (LED OFF).
Change the position of the magnets as necessary and secure them
definitively.
4. START-UP
Program the control unit according to your needs, as per relevant
instructions.
Power up the system and check the condition of the LEDs according to
the table in the control unit instructions.
When you have run the automated system test (par.5), secure the pro-
tective housing on the operator, using the supplied screws as shown in
fig. 15.
5. AUTOMATED SYSTEM TEST
Check operating efficiency of the automated system and all accessories
connected to it.
Hand the customer the “User’s Guide” page and explain how the automa-
ted system operates correctly and how it should be used.
8.
1.
2.
3.
Fig. 14
Fig. 14
Fig. 15
Fig. 15
6. MANUAL MODE OPERATION
If the gate has to be moved manually due to a power cut or fault of the
automated system, use the release device as follows:
Using a coin, turn the lock clockwise until it stops (Fig. 16 ref.
a
)
Pull the lever as shown in fig. 16 ref.
b
.
Open and close the gate manually.
1
2
Procedure for restoring normal operation:
Cut power to the system.
Position the gate at about halfway of opening travel.
Take the release lever back into its position;
Using a coin, turn the lock anti-clockwise until it stops;
Restore power to the system.
when power is restored, command another complete opening
cycle.
before sending a pulse, make sure that the gate cannot be moved
manually.
7. SPECIAL APPLICATIONS
Applications other than those in this manual are EXPRESSLY PROHIBITED.
8. MAINTENANCE
To ensure correct long-term operation and a constant level of safety, we
advise you to generally check the system every 6 months. In the “User’s
Guide” booklet, there is a form for recording jobs.
9. REPAIRS
The User must not in any way attempt to repair or to take direct action and
must solely contact qualified GENIUS personnel or GENIUS service centres.