background image

0

ENGLISH

 - To avoid damaging the operator and/or interrupting operation of the 

automated system, leave a distance of about 40 mm from the safety 

mechanical stops.

 

- Make sure that at the end of both the opening and closing manoeuvre, 

the relevant contact stays active (LED OFF).

Change  the  position  of  the  magnets  as  necessary  and  secure  them 

definitively.

4. START-UP

Program  the  control  unit  according  to  your  needs,  as  per  relevant 

instructions.

Power up the system and check the condition of the LEDs according to 

the table in the control unit instructions.

When you have run the automated system test (par.5), secure the pro-

tective housing on the operator, using the supplied screws as shown in 

fig. 15.

5. AUTOMATED SYSTEM TEST

Check operating efficiency of the automated system and all accessories 

connected to it.

Hand the customer the “User’s Guide” page and explain how the automa-

ted system operates correctly and how it should be used.

8.

1.

2.

3.

Fig. 14

Fig. 14

Fig. 15

Fig. 15

6. MANUAL MODE OPERATION 

If the gate has to be moved manually due to a power cut or fault of the 

automated system, use the release device as follows:

Using a coin, turn the lock clockwise until it stops (Fig. 16 ref. 

a

)

Pull the lever as shown in fig. 16 ref. 

b

.

Open and close the gate manually.

1

2

Procedure for restoring normal operation:

Cut power to the system.

Position the gate at about halfway of opening travel.

Take the release lever back into its position;

Using a coin, turn the lock anti-clockwise until it stops;

Restore power to the system.

  when  power  is  restored,  command  another  complete  opening 

cycle.

 before sending a pulse, make sure that the gate cannot be moved 

manually.

7. SPECIAL APPLICATIONS

Applications other than those in this manual are EXPRESSLY PROHIBITED.  

8. MAINTENANCE

To ensure correct long-term operation and a constant level of safety, we 

advise you to generally check the system every 6 months. In the “User’s 

Guide” booklet, there is a form for recording jobs.

9. REPAIRS

The User must not in any way attempt to repair or to take direct action and 

must solely contact qualified GENIUS personnel or GENIUS service centres.

1.

2.

3.

1.

2.

3.

4.

5.

Fig. 16