Blower / motor / fan assembly replacement
Replace the blower / motor / fan assembly as shown below:
Note that the blower / motor / fan assembly is designed to fit tightly into the chassis. A weak solution of a
household liquid soap and water may be used as a lubricant on the outer rubber sleeve during installation.
After installing a new blower / motor / fan assembly, perform the following checks:
•
NOTICE
Replacement or servicing beyond the tasks described above requires sending the device(s) back to a
Gentex authorized repair facility.
5.3.1.
Visual inspection
Check all parts thoroughly and replace damaged parts if necessary.
5.3.2.
Checking the battery pack capacity
5.3.3.
Replacing or charging the battery pack
See 3.2.2
5.3.4.
Replacing the filter
•
All filters and cartridges must be replaced when the LED indicator is illuminated red.
The red LED and audible alarm indicates that the HE (HEPA) filter material is plugged
or blocked to the degree where Pureflo ESM+ can no longer provide sufficient airflow
to the respirator user.
•
Install the new filter as show in Section on page. Twist the filter counterclockwise to
engage the thread and then tighten clockwise to fit the filter onto the respirator.
•
The Pureflo ESM+ has no end of service life detection (gases and vapors)
•
Replace cartridges for protection against vapor/gases according to your employers
change out schedule or sooner if contaminant is detected within the breathing zone
of the respirator.
•
Never attempt to clean the HE filter cartridge by knocking or blowing out
accumulated material. Doing so will damage the filter media.