4.5 Optional Cathodic Protection Interface System
An optional cathodic protection interface system is available for use with the model P-5050
TEG. It provides for adjustment and monitoring of power to a Cathodic Protection (CP) load.
The anode and cathode cables enter the cabinet at the bottom and connect directly to a
heavy duty terminal block. A 0 to 1 Ω 300 Watt variable resistor is provided for adjusting the
output power applied to the CP system.
The main parts of the CP interface system are shown in Figure 8.
Enclosure:
The CP interface system is enclosed within a weather resistant 304 SS enclo-
sure. Enclosure features include a lock-able cabinet door, 1 in. conduit opening on the bot-
tom for customer CP wires, and separate area within the enclosure for the variable power
resistor.
Meter:
The dual scale meter displays voltage at the terminal block, and current when the
PUSH TO READ AMPS button is depressed. The meter is accurate to ± 3% of full scale.
4.6 Optional Remote Start System (TEG Controller board)
An Optional Remote Start system (TEG Controller board) is available for use with the TEG.
The TEG Controller board provides a method of starting and stopping the TEG either locally
or remotely, using on-board buttons, SCADA signal interface or system measurements.
The pressure switch is connected to the TEG Controller when it is added to the system.
Only if there is fuel available, by the closed pressure switch, will any requests to start be
attempted.
The TEG Controller provides an ignition request signal to the spark ignition control system
when it is has been requested to start and removes the ignition request signal when it is
requested to stop. During the time it is requesting ignition, the TEG Controller monitors the
Lockout signal from the SI system. If it receives a Lockout signal, a reset must be received,
either locally or remotely, before any start requests can be re-attempted.
Note: The certified Ignition Control Module (SI) is responsible for the ignition sequence and
control of the fuel valve and spark generation.
Any button press causes the TEG Controller’s operating mode to be switched to Local
mode. Any Auto or SCADA starts are ignored until the mode times out and switches back
to Remote operating mode. Stop requests are always accepted and acted upon in either
mode.
Turning Auto functionality on enables the system measurement controlled operation in
Remote mode.
Summary of Contents for P-5050
Page 4: ......
Page 8: ......
Page 44: ...Gentherm Global Power Technologies 5 12 P 5050 62553 rev 8 ...
Page 46: ...Gentherm Global Power Technologies 6 2 P 5050 62553 rev 8 ...
Page 60: ...Gentherm Global Power Technologies 8 10 P 5050 62553 rev 8 ...
Page 98: ...Gentherm Global Power Technologies 14 4 P 5050 62553 rev 8 ...