Gentherm Global Power Technologies 5-3
P-5050
62553 Rev.8
5.5 Mounting
Mount the TEG to a firm and stable base, using 1/4-20 bolts of material suitable for the
environment. See Figure 11 for mounting hole locations. The base must be level and sturdy
enough to support the 41 kg (90 lb) mass of the TEG.
Caution: Operation of the TEG in locations where cooling air flow may be
obstructed will cause overheating of the TEG. Allow a minimum of 150
mm (6 in.) clearance under the cooling fins and 600 mm (36 in.) above
the top of the fin duct. Locate the TEG to avoid flooding interfering with
the flow of cooling air.
5.6 Supplying Fuel
This topic describes how to connect the fuel supply and gives background information for
consideration when providing fuel to the P-5050 TEG.
12.06 306
10.53 267
MOUNTING
HOLES
CP PANEL
(OPTIONAL)
62593 rev1
FUEL INLET
1/4'' FNPT
39.12[994]
17.99[457]
2.96
75
31.11[790]
18.00 457
MOUNTING HOLES
Figure 11
Model P-5050 Mounting Dimensions