Gentherm Global Power Technologies 8-8
P-5050
62553 rev.8
Adjusting the variable resistor can be done simply while the system is running, by loosen-
ing the slide ring on the resistor and moving it up or down on the resistor. Check the power
changes by using the meters provided in the enclosure or using a hand held multi-meter to
easily see the change in power when adjusting the variable resistor. Once the resistor has
been adjusted to give the desired power output, check that all electrical connections are
tight, and lastly recheck that the desired power output has not changed.
Note: TEG fuel pressure may be adjusted to fine tune the CP output. Fuel pressure within
10% of that marked on the data plate is recommended to prevent flame out.
Figure 24
CP Interface System,
Series Wiring Diagram
Figure 25
CP Interface System,
Parallel Wiring Diagram