16
1
7
6
2
3
4
5
A
MOD. C330/03
A
MOD. C330/24 - C330/50
EN
Rev. 01 - 05/2013 - Cod. CM31710 -
Instruction manual
Compressor Mod. C330
1)
Connect the appliance to the power supply
(1)
by plugging it in.
2)
Switch on the appliance using the “ON-OFF”
switch
(3)
ensuring it is in the “ON (I)” position
(the appliance is operational until it reaches a
maximum operating pressure of 10 bar, after
which, it switches of automatically.
3)
Regulate the outlet pressure using the rele-
vant regulator
(4)
according to the utensil
used and type of work. Control the pressure
displayed by the relevant gauge
(6)
.
Do not FUllY SCREW tHE oUlEt
PRESSURE GaUGE (4) oR YoU RiSK
DaMaGinG tHE MEMEBRanE.
4)
Connect the utensil to the air pipe (extension).
5)
Connect the air pipe (extension) to the air
outlet spigot
(5)
.
aiR PiPES (EXtEnSionS), ConnECtionS anD UtEnSilS WHiCH ConFoRM to DEtailS aS SPECiFiED in
tHE inStRUCtion ManUalS PRoViDED BY tHE RElEVant ManUFaCtURERS MUSt BE USED.
it iS StRiCtlY FoRBiDDEn to USE UnSUitaBlE aiR HoSES (EXtEnSionS), FittinGS anD toolS tHat Do not
CoMPlY WitH CURREnt REGUlationS.
6)
Carry out operations (the appliance will re-start automatically in the instance where the operating pressure falls below
7 bar).
7)
Upon termination of operations, switch of the appliance as described in Paragraph 27.
27. APPLIANCE DEACTIVATION
At the end of operations, switch of the appliance as follows:
1)
Switch of the appliance using the “ON-OFF” switch
(3)
ensuring it is set to “OFF (0)”.
2)
Disconnect the appliance from the power supply
(1)
by unplugging it.
3)
Disconnect the utensil from the air pipe (extension).
4)
Disconnect the air pipe (extension) from the appliance air outlet spigot
(5)
.
5)
Drain the tank condensate pump only once the work cycle is terminated
(A)
.