RESET INTERVENTION – THERMAL RESTORE
In the instance where current overload and/or a short circuit of the appliance electrical system is noted, the thermal
restore intervenes, disabling the electric motor.
To carry out the reset intervention, proceed as follows:
1)
Turn the “ON-OFF” switch
(3)
to the “OFF (0)” position.
2)
Press the thermal restore button
(B)
.
3)
Wait a few moments before restarting the appliance.
iF, AFTeR CARRYing OUT TheRMAl ResTORe, The APPliAnCe DOes nOT ResTART, The QUAliFieD OPeRA-
TOR MUsT ReQUesT The inTeRVenTiOn OF MAinTenAnCe PeRsOns AnD/OR The AUThORiseD sUPPlieR.