19. SAFETY dEViCES AdOPTEd
SAFETY VALVE (10):
a certified safety valve (set to 10.5 bar),
installed to the pneumatic system, under the pressure switch.
It tackles over-pressure in the instance where, owing to ano-
malies, the pressure switch does not function. safety valve in-
tervention ensures the operator switches off the appliance and
requests the support of maintenance persons.
PRESSURE SWiTCH (2):
an electro-pneumatic device (set to a
minimum of 7 bar and a maximum of 10 bar) installed to the
pneumatic system. It serves to control the automatic start-up of
the appliance when the operating pressure comes down to 7 bar
and the automatic close-down when the pressure reaches 10 bar.
FAn COVER (19):
fixed protection made of plastic attached
using screws fixed to the twin cylinder pump system base. It
serves to stop accidental contact with the cooling fan when in
motion.
TAnK PRESSURE GAUGE (15):
a measuring device installed to
the appliance tank. It displays the compressed air pressure in-
side the tank.
OUTLET PRESSURE GAUGE (8):
a measuring device installed
to the appliance pneumatic system above the air outlet spigot.
It displays the outlet pressure, which can be
adjusted using the relative pressure regulator
(0÷10 bar)