24.  COMMAnd dEViCES

The command devices are:

 

1)

 Electrical supply cable

 

2)

 Pressure switch

 

3)

 “ON-OFF” switch

 

4)

 Outlet pressure regulator

 

5)

 Air outlet spigot (regulator)

 

5a)

 Air outlet spigot (tank)

 

6)

 Tank pressure gauge

 

7)

 Tank outlet gauge

 

8)

 safety valve

 

9)

 Black switch (not connected)

Summary of Contents for C660/100

Page 1: ...Instruction Manual Compressors C660 100 EK480 100 EK660 100 EK480 10 EN...

Page 2: ......

Page 3: ...UNPACKING 16 15 LOCATION 16 16 STORAGE 16 17 ELECTRICAL CONNECTION 17 18 AIR PIPE EXTENSION AND UTENSILS CONNECTION 18 19 SAFETY DEVICES ADOPTED 19 20 SAFETY SIGNS 20 21 PERSONAL PROTECTIVE EQUIPMENT...

Page 4: ...k cap do not touch 4 Condensate pump 5 Support feet 6 Air outlet spigot regulator 6a Air outlet spigot tank 7 Outlet pressure regulator 8 Tank outlet gauge 9 Non return valve 10 Safety valve 11 Adjust...

Page 5: ...1 2 7 8 6 6a 15 10 14 4 21 20 18 19 18 20 11 3 16 9 12 5 17 22 3 17 7 6 1 2 15 8 19 5 18 10 13 19 20 16 14 21 9 21 11 Instruction Manual Compressors C660 100 EK480 100 EK660 100 EK480 10 MAN_E_C_A001...

Page 6: ...al power kW 4 4 2 8 3 3 4 2 8 3 Max operating pressure bar 10 Level of output noise levels A at the work stations Leg 2006 42 CE dB 85 86 87 84 86 87 Driveshaft rotation speed rpm 1400 1400 1700 1400...

Page 7: ...16 EC recast 2014 30 UE Directive of the European Parliament and of the Council of 26 February 2014 replacing 2004 108 EC Directive of the European Parliament and of the Council of 15 December 2004 on...

Page 8: ...480 10 MAN_E_C_A001 11 2019 4 CE LABEL The CE label serves as evidence of the appliance s compliance with essential health and safety requirements as specified by the Machinery Directive 2006 42 CE It...

Page 9: ...safe place within close proximity of the appliance THE PRESENT INSTRUCTION MANUAL FORMS AN INTEGRAL PART OF THE APPLIANCE AND MUST BE KEPT FOR FUTURE REFERENCE AND UP UNTIL THE END OF APPLIANCE LIFE I...

Page 10: ...MAINTENANCE PERSON A qualified technician capable of carrying out exclusive interventions on mechanical pneumatic parts in order to oversee the regulation maintenance and or repairs even with protecti...

Page 11: ...ard and extraordinary maintenance interven tions and or operations which are not presently included which necessitate specialist knowledge of the appliance whilst using the dedicated personal safety d...

Page 12: ...e on the website www gentilinair com within seven days of purchase and b have completed the registration form completely and accurately filling in the required fields with exact complete and true info...

Page 13: ...ith sufficient lighting ventilation with temperature and air humidity va lues as per details provided in Paragraph 2 in compliance with legislation governing health and safety in the work place in for...

Page 14: ...IANCE WITH LEGISLATION GOVERNING EMISSIONS NOISE IN FORCE IN THE COUNTRY OF USE DURING USE ENSURE THAT UNAUTHORISED PERSONS DO NOT COME WITHIN PROXIMITY OF THE APPLIANCE THE APPLIANCE MUST BE KEPT OUT...

Page 15: ...N AND MOVEMENT OF THE APPLIANCE The machine can be manually carried by an operator using the handle A and the wheels B TRANSPORTATION OF THE APPLIANCE MUST BE CARRIED OUT BY TWO QUALIFIED OPERATORS IN...

Page 16: ...CCORDING TO THE VARIOUS WASTE MATERIALS AND IN COMPLIANCE WITH LEGISLATION CURRENTLY IN FORCE IN THE COUNTRY OF USAGE 15 LOCATION The appliance must be placed in a work place which satisfies the chara...

Page 17: ...SUITED TO THE INTENDED USAGE LABELLED WITH CE IF SUBJECT TO THE LOW VOLTAGE DI RECTIVE 2006 95 CE AND CONFORM TO THE REQUIREMENTS AS SPECIFIED IN THE LEGISLATION CURRENTLY IN FORCE IN THE COUNTRY OF A...

Page 18: ...e appliance air outlet tank or regulator spigot rif 6 6a THE MANUFACTURER DECLINES ANY RESPONSIBILITY FOR DAMAGE TO PERSONS ANIMALS AND OBJECTS CAUSED BY THE INOBSERVATION OF THE ABOVE DESCRIBEDWARNIN...

Page 19: ...umatic device set to a minimum of 7 bar and a maximum of 10 bar installed to the pneumatic system It serves to control the automatic start up of the appliance when the operating pressure comes down to...

Page 20: ...S VISIBLE SAFETY SIGNS WHICH ARE DAMAGED MUST BE REPLACED ASK FOR A RE PLACAMENT FROM THE MANUFACTRER OR THE AUTHORISED SUPPLIER REMOVING AND OR DAMAGING THE SAFETY SIGN ATTACHED TO THE APPLIAN CE IS...

Page 21: ...er of burns upon accidental contact with the twin cylin der pump system and the electric motor SEVERITY OF DAMAGE Mild damage normally reversible LIABILITY Liability may be incorporated in the instanc...

Page 22: ...the appliance next to the command devices in order to com mand the activation and deactivation of the compressor to carry out connection discon nection of the utensils reading of the gauge and the re...

Page 23: ...660 100 EK480 100 EK660 100 EK480 10 MAN_E_C_A001 11 2019 24 COMMAND DEVICES The command devices are 1 Electrical supply cable 2 Pressure switch 3 ON OFF switch 4 Outlet pressure regulator 5 Air outle...

Page 24: ...rsons are in close proximity of the appliance Ensure that safety devices are not damaged and that they are correctly installed and ope rational see Paragraph 19 Ensure that the appliance is correctly...

Page 25: ...MANUFACTURTER DECLINES ANY RESPONSIBILITY FOR THE OUTCOME FOL LOWING USAGE AS THIS IS DEPENDENT ON THE UTENSIL USED AND THE PRO FESSIONAL SKILLS OF THE AUTHORISED OPERATORS THE AUTHORISED OPERATORS MA...

Page 26: ...sition the appliance is operational until it reaches a maximum operating pressure of 10 bar after which it switches off automatically Regulate the outlet pressure using the relevant regulator 4 accord...

Page 27: ...Carry out operations the appliance will re start automatically in the instance where the operating pressure falls below 7 bar Upon termination of operations switch off the appliance as described in Pa...

Page 28: ...e electrical sy stem is noted a safety devicerestore intervenes disabling the electric motor To carry out the reset intervention proceed as follows Turn the switch 3 to the OFF 0 position Press the th...

Page 29: ...Appliance emergency stop can be carried out by turning the ON OFF switch 3 to the OFF 0 position In order to avoid any possible danger authorised operators must carry out the following operations IMM...

Page 30: ...scribed in Paragraph 26 31 STANDARD MAINTENANCE All activities carried out to ensure use and operation of the appliance via various interven tion types regulation valve checks cleaning of air filters...

Page 31: ...g Electrical cable and plug Visual check of usage status Tank Upon termination of each work cycle rest the ap pliance on the ground and drain the tank conden sate pump opening the condensate pump A EV...

Page 32: ...THORISED SUP PLIER MUST BE REQUESTED 33 END OF SERVICE LIFE When disposing of the appliance current legislation in force must be considered Dispose of the various component materials separately plasti...

Page 33: ...e start No electrical supply Check that the switch 3 is in the ON I position Check that the electrical plug is fun ctioning correctly and is correctly plugged in Check that any extensions used and the...

Page 34: ...air The tank is not pres surised Switch on the appliance and wait until the tank fills checking the pressure of the re levant gauge Incorrect regulation of the outlet pressu re Check that the value di...

Page 35: ...ressure switch fault Contact an authorised Supplier Air loss from the pres sure switch when ap pliance is off Unclean or worn return valve Contact an authorised Supplier The appliance vibra tes and or...