STAndARd MAinTEnAnCE TABLE
FREQUEnCY inTERVEnTiOn AREA
inTERVEnTiOn TYPE
OnCE A dAY
safety devices.
Ensure they are intact, correctly installed and
functioning.
Electrical cable and plug. Visual check of usage status.
Tank.
upon termination of each work cycle, rest the ap-
pliance on the ground and drain the tank conden-
sate pump opening the condensate pump
(A)
.
EVERY WEEK
Wheels.
Wheel pressure check. subsequently pump up
with compressed air up to a maximum of 2.5 bar.
N. 4 air filters.
unscrew the screws
(1)
.
remove the cover
(2)
.
Extract the filter
(3)
and clean it using compres-
sed air.
Reassemble the filters and properly reposition
the lid.
NOTE: REPLACE IN THE INSTANCE WHERE IT