SCHEDA TECNICA DRYTEC
L’essicatore a membrana DRY TEC raggruppa in
un unico blocco tutti i seguenti organi:
(OHPHQWR ÀOWUDQWH ¸ VHSDUDWRUH GL FRQGHQVD
,
alloggiato nella testata inferiore d’ingresso aria
FRPSUHVVD /D VXD IXQ]LRQH q TXHOOD GL VHSD
-
UDUHODIDVHOLTXLGDGLFRQGHQVDSHUFRVuFRQ
-
vogliare la sola fase di vapore acqueo verso il
QXFOHRGHOOHPHPEUDQHDÀEUHFDYH
Dispositivo antipulsatorio:
TXHVWR q LQWHOOLJHQ
-
WHPHQWH DOORJJLDWR DOO·LQWHUQR GHO ÀOWUR VWHVVR
H KD SHU IXQ]LRQH TXHOOD GL VPRU]DUH LO ÁXVVR
pulsatorio pertinente al moto dei compressori
DSLVWRQLVDOYDJXDUGDQGRFRVuOHÀEUHGDXQR
stress indesiderabile.
Scaricatore automatico della condensa: nes-
VXQ FRPSURPHVVR q FRQFHVVR WUDWWDVL GL XQ
vero scaricatore a galleggiante che scarica
in funzione dell’innalzamento del livello della
condensa e non di un dispositivo parziale che
SRVVDVFDULFDUHVRORDÀQHSRPSDWD
Nucleo disidratatore:
TXHVWRqFRVWLWXLWRGDXQD
IDVFLRGLPHPEUDQHDÀEUHFDYHODFXLFDUDW
-
WHULVWLFDqTXHOODGLGLIIRQGHUHRYYHURFHGHUH
l’umidità verso l’esterno, attraverso una parete
porosa caratterizzata da un cosiddetto taglio
molecolare selettivo che consente la migrazio-
ne della sola molecola di vapor acqueo, men-
tre le molecole di azoto e ossigeno costituenti
LO ÁXVVR G·DULD ULPDQJRQR DOO·LQWHUQR GHO WXER
capillare.
Ugello di rigenerazione intercettato:
DOÀQHGLID
-
vorire l’estrazione dell’umidità “pompata” attra-
verso la parete porosa, una percentuale (~10%)
d’aria secca viene espansa attraverso un ugello
FKHIDGHÁXLUHTXHVWDFRUUHQWHGLULJHQHUD]LRQH
LQFRQWURÁXVVRVXOODWRHVWHUQRGHOOHPHPEUDQH
DÀEUHLQWUHFFLDWH)OHVVLELOHHUD]LRQDOHLQIXQ
-
zione della grandezza del compressore, l’ugello
può essere cambiato in modo che una unica
membrana copra l’intera gamma di portate
QRPLQDOPHQWH GD H 1,PLQ DG RJQL
modo ottimizzabile in funzione delle proprie esi-
genze del Costruttore).
)LOWUREDWWHULFLGDRS]LRQH
la testata di uscita
q JLj SUHGLVSRVWD SHU DOORJJLDUH XQ HOHPHQWR
ÀOWUDQWH DVHWWLFR /R VL SURSRQH LQ RS]LRQH LQ
modo da non aggravare il costo primo delle
apparecchiature destinate a mercati più po-
veri, cosicché altrettanto soddisfare senza ul-
teriori trasformazioni le esigenze della clientela
più rigorosa. I componenti di questo elemento
sterile sono in accordo a quanto regolamenta-
to dalla normativa FDA (Food Drug Administra-
WLRQ HG q VWHULOL]]DELOH LQ DXWRFODYH VHFRQGR
criteri convenzionali.
*(17,/,165/7HKQLVNDLVGHSDUWDPHQWV
INSTRUCTION MANUAL
EN
MAN_CNC3_A001
DRYTEC TECHNICAL SHEET
T
KH '5< 7(& PHPEUDQH GU\HU FROOHFWV DOO RI WKH
IROORZLQJSDUWVLQDXQLTXHEORFN
)LOWHULQJHOHPHQW¸FRQGHQVDWHVHSDUDWRU
, hou-
sed in thelower compressed air input head. Its
function is to separate the condensate liquid
phase and then convey just the water vapour
SKDVH WRZDUGV WKH FRUHV RI WKH KROORZ ÀEUH
membranes.
Anti-pulse device: this is intelligently housed in-
VLGHWKHÀOWHULWVHOIDQGGDPSHQVWKHSXOVHÁRZ
pertinent to the movement of the piston com-
SUHVVRUVWKXVSURWHFWLQJWKHÀEUHVIURPXQGHVL
-
rable stress.
Automatic condensate drain: no compro-
PLVH LV DOORZHG LW LV D UHDO ÁRDW GUDLQ WKDW
operates depending on the rising level of
condensate and not of a partial device
that can only drain at the end of pumping.
&RUHGHK\GUDWRU
this is made up from a bundle
RI KROORZ ÀEUH PHPEUDQHV ZKRVH FKDUDFWH
-
ristic is that of distributing, i.e. transferring the
humidity towards the outside, through a porous
wall characterised by a so-called selective mo-
lecular size, which allows migration just of the
water vapour molecule, while the molecules of
QLWURJHQDQGR[\JHQPDNLQJXSWKHDLUÁRZUH
-
main inside the capillary tube.
Regeneration nozzle cut-off: in order to favour
the extraction of the humidity “pumped” throu-
gh theporous wall, a percentage (~10 %) of dry
air is expanded through a nozzle, which ma-
NHV WKLV UHJHQHUDWLRQ FXUUHQW ÁRZ LQ EDFNÁRZ
mode on the external side of the intertwined
ÀEUHPHPEUDQHV)OH[LEOHDQGUDWLRQDOGHSHQ
-
ding on the size of the compressor, the nozzle
can be changed so that a unique membrane
FRYHUVWKHHQWLUHUDQJHRIÁRZUDWHVQRPLQDOO\
IURP DQG 1,PLQ ZKLFK FDQ EH RSWL
-
mised depending on customer requirements).
$QWLEDFWHULDOÀOWHURSWLRQ
the output head is
DOUHDG\VHWXSWRKRXVHDQDQWLVHSWLFÀOWHULQJ
element. It is offered as an optional so as not to
increase the purchase cost of the equipment is
not needed, so as to satisfy the more deman-
ding customer without further transformations.
The components of this sterile element are in
compliance with that governed by the FDA
Standard (Food and Drug Administration) and
can be sterilised in autoclave according to
conventional criteria.