42
MAN0340001 - 07/2019
www.gentilinair.com
Instruction Manual - Clinic 3.40 Compressors
pRobLEm
CauSE
SoLutIoNS
Intervention of the sa-
fety valve.
Faulty pressure switch.
See the maintenance technicians
or contact an Authorized Reseller.
Air leak from the valve
of the pressure switch
with machine stopped.
Check valve is dirty or worn.
The machine vibrates
and/or makes a lot of
noise.
Mechanical failure.
Frequent starts and
low efficiency.
Dirty air filters.
maINtENaNCE
This is the set of activities designed to maintain the conditions of use and
operation of the machine, through various types of intervention (adjustments,
visual inspection, recovery levels, etc.) performed by the maintenance tech-
nician or by the manufacturer’s technician at the frequency forecast.
tHE autHoRIZED opERatoRS SHouLD pERfoRm oNLY tHE maINtENaN-
CE WoRkS REQuIRED IN aCCoRDaNCE WItH tHEIR SpECIfIC pRofESSIo-
NaL CompEtENCE aND upoN CoNSENt of tHE SupERVISoR IN CHaRgE.
It IS foRbIDDEN to autHoRIZED opERatoRS to LEaVE tHE maCHINE WI-
tHout SupERVISIoN DuRINg tHE maINtENaNCE WoRkS. tHEY SHouLD
aLSo pRotECt tHE pLaCE of WoRk WItH a WHItE/RED CHaIN aND EXpo-
SE aDEQuatE NotICE of DaNgER aND pRoHIbItIoN foR WoRkS IN pRogRESS.
poINt of INtERVENtIoN
taNk
tYpE of INtERVENtIoN
CoNDENSatE DRaIN