11
Menu
Description
Factory setting and
(max. / min values)
D1- Language
Display language can be changed
D1 : English
(English / Dansk /
Deutch / Svenska)
D2 - Screensaver time
Idle time before screensaver activates.
0 = screensaver off
D2: 10 min
(0 - 600 min)
D3 - Display lock time
Lock time active when touching lock symbol on main screen
D3: 5 sec
(0 - 120 sec)
D4 - Password
Main menu password:
Choose password for locking main menu access. If password is
selected - the next time the user trying to access the main menu
will be prompted for entry of password. To deactive password
promt use 0000 as password
Service menu password:
Choose password for locking service menu access. If password is
selected - the next time the user trying to access the main menu
will be prompted for entry of password. To deactive password
promt use 0000 as password
-
D5 - Firmware update
Optima 270 controller and display can be firmware updated by use
of a micro-SD card inserted into the SD card reader of the Optima
touch display. Touch "start update" when the SD card containing
the latest firmware has been inserted into the card reader to
update the controller and display.
-
EA - Save/load settings
EA1 - Save settings
Saves the settings from the Optima270 controller to the display
EA2 - Load settings
Loads settings stored in EA1 and transfers data to a new Optima
270 PCB
-
EB - Fan speed levels
EB1 - Level 1 Supply air
Level 1, which is the lowest speed, is usually used when there is
nobody home. Both fans can be configured independently of each
other for all levels so that the air flow in the supply air and in the
extract air is equal, which provides optimal operation.
The adjustment of the system must be performed with specialised
air measuring equipment and can be done without using the main
regulating damper.
Configuring the air flows without expert advice is not
recommended. Incorrect configuration can lead to major energy
consumption or unpleasant indoor climate.
Setting option: between 0 and 100%.
EB2 - Level 2 Supply air
Level 2 is the recommended speed of the system for providing
optimal indoor climate. It should be adjusted to the ventilation
requirement of the dwelling.
Setting option: between 0 and 100%.
EB1: 30%
(0-100%)
EB2: 50%
(0-100%)