background image

17

EN

CARE AND CLEANING

Handle measuring instruments with care. Clean with soft cloth only after any use. If necessary damp 

the cloth with some water. If the instrument is wet clean and dry it carefully. Pack it up only if it is per-

fectly dry. Transport in original container / case only.

INTENDED USE OF INSTRUMENT

The instrument emits a visible laser beam in order to carry out the following measuring tasks:

Setting up plumbing points.

EXCEPTIONS FROM RESPONSIBILITY

1.  The user of this product is expected to follow the instructions given in the user manual. Although 

all instruments left our warehouse in perfect condition and adjustment the user is expected to 

carry out periodic checks of the product’s accuracy and general performance.

2.  The manufacturer, or its representatives, assumes no responsibility of results of a faulty or 

intentional usage or misuse including any direct, indirect, consequential damage, and loss of 

profits.

3.  The manufacturer, or its representatives, assumes no responsibility for consequential damage, 

and loss of profits by any disaster (earthquake, storm, flood etc.), fire, accident, or an act of a third 

party and/or a usage in other than usual conditions.

4.  The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of 

profits due to a change of data, loss of data and interruption of business etc., caused by using the 

product or an unusable product.

5.  The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of 

profits caused by usage other than explained in the user manual.

6.  The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong 

movement or action due to connecting with other products.

Please note:

If you return instruments for repair / for adjustment to us please disconnect batteries or rechargeable batteries 
from the instrument - this is for safety reasons! 
Thank you.

LASER CLASSIFICATION 

The instrument is a laser class 2 laser product according to DIN IEC 60825-1:2014.

It is allowed to use the unit without further safety precautions.

The eye protection is normally secured by aversion responses and the blink reflex.

The laser instrument is marked with class 2 warning labels.

Laser 

2

IEC 60825-1:2014

P ≤ 1 mW @ 635 - 670 nm

www.geo-fennel.de

GERMANY

Laser 

2

IEC 60825-1:2014

P ≤ 1 mW @ 515 - 530 nm

www.geo-fennel.de

GERMANY

Summary of Contents for 310100

Page 1: ...BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI www geo fennel de www geo fennel com www geo fennel fr DE EN FR FLP 150 GREEN...

Page 2: ...n helfen das Ger t sachgem zu bedienen Bitte lesen Sie ins besondere auch die Sicherheitshinweise vor der Inbetriebnahme aufmerksam durch Nur ein sachge rechter Gebrauch gew hrleistet einen langen und...

Page 3: ...Stromversorgung 10 h Li Ion Temperaturbereich 10 C bis 45 C Staub Wasserschutz IP 54 Gewicht 2 8 kg EIGENSCHAFTEN Einfach zu bedienendes Laserlot mit zwei entgegengesetzten Laserpunkten oben und unten...

Page 4: ...lternativ mit Alkaline Batterien betrieben werden Batteriefach ffnen Alkaline Batterien einlegen Polarit t beachten und Batteriefach wieder ver schlie en Wenn der Laserpunkt schw cher wird muss der Ak...

Page 5: ...Ziel scharfstellen Das Ger t ist nun fertig horizontiert und der obere und untere Lotpunkt sowie die optische Achse sind konzentrisch Wenn das Ger t ber dem fixen Bodenpunkt exakt ausgerichtet ist den...

Page 6: ...gang in 90 Schritten wiederholen bis die R hrenlibelle zentriert ist Schrauben und Klemmschraube wieder festziehen JUSTIERUNG DER DOSENLIBELLE Zentrierung der Dosenlibelle berpr fen wenn die Blase nic...

Page 7: ...schwach Akku ist leer Akku laden oder Laserdiode ist defekt Ger t zur Reparatur einsenden 4 Der Laserpunkt ist zu gro Fokussierung ist nicht in Ordnung justieren gem Anleitung oder Laserpunkt und Opt...

Page 8: ...anspruch besteht nur bei bestimmungsgem er Verwendung Mechanischer Verschlei und u erliche Zerst rung durch Gewaltanwendung und Sturz unterliegen nicht der Garantie Der Garantieanspruch erlischt wenn...

Page 9: ...inn 3 Der Hersteller und sein Vertreter haften nicht f r Folgesch den und entgangenen Gewinn durch Naturkatastrophen wie z B Erdbeben Sturm Flut usw sowie Feuer Unfall Eingriffe durch Dritte oder eine...

Page 10: ...Please read the manual carefully particularly the safety instructions A proper use only guarantees a longtime and reliable operation geo FENNEL Precision by tradition Contents 1 Supplied with A 2 Powe...

Page 11: ...er class red 2 Accuracy 1 mm 1 5 m Power supply 10 h Li Ion Temperature range 10 C up to 45 C Dust water protection IP 54 Weight 2 8 kg CHARACTERISTICS Easy to use with two laser plummets up and down...

Page 12: ...1 2 3 4 5 7 8 9 10 11 6 INSTALL THE BATTERY Both the standard Li Ion battery or 2 x AA Alkaline batteries can be used LI ION BATTERY PACK The instrument comes with Li Ion rechargeable battery pack Ope...

Page 13: ...is are concentrical When the istrument is centered over a known point turn the ON OFF plumb point upwards and or ON OFF plumb point to the ground clockwise until you hear a click The integrated filter...

Page 14: ...ion with the plate level adjusting screw with the adjusting pin supplied in the tool kit and half of the deviation with a footscrew Repeat the above procedures until the plate level is centred in all...

Page 15: ...low charge the batteries or The laser diode is defect contact your service provider 4 The laser point is too large Focussing error adjust according to the user manual or The optical axis is not parfoc...

Page 16: ...riod and upon proof of purchase the product will be repaired or replaced with the same or similar model at manufacturers option without charge for either parts or labour In case of a defect please con...

Page 17: ...storm flood etc fire accident or an act of a third party and or a usage in other than usual conditions 4 The manufacturer or its representatives assumes no responsibility for any damage and loss of pr...

Page 18: ...avec soin tout particuli rement les consignes de s curit de ladite notice avant la mise en service de votre appareil Un emploi appropri est l unique moyen de garantir un fonc tionnement efficace et d...

Page 19: ...cision 1 mm 1 5 m Alimentation 10 h Li Ion Plage de temp rature 10 C 45 C tanch it IP 54 Poids 2 8 kg CARACT RISTIQUES Un laser d aplomb laser facile utiliser avec 2 points laser oppos s l un vers le...

Page 20: ...se 16 Cible 14 12 13 15 16 1 2 3 4 5 7 8 9 10 11 6 METTRE EN PLACE LES BATTERIES L instrument fonctionne aussi bien sur batterie que sur piles PACK BATTERIES LI ION Le laser est livr avec une batterie...

Page 21: ...r le point de sol connu tournez droite le bouton MARCHE ARR T du point laser vers le haut du point laser au sol jusqu au click Le point laser est maintenant sous tension Le filtre int gr prot ge les y...

Page 22: ...ration des pas de 90 jusqu ce que la bulle de la nivelle d alidade reste au centre pour n import quelle direction Visser les vis et les vis de blocage R GLAGE DE LA NIVELLE SPH RIQUE V rifier d abord...

Page 23: ...tterie est d charg e charger la batterie ou La diode laser est en panne envoyer l instrument au SAV 4 Le point laser est trop largi La mise au point n est pas r gl e correctement r glage selon instruc...

Page 24: ...le manque des propri t s pr vues Le droit la garantie n est valable que si l utilisation du niveau a t conforme aux pr scriptions En sont exclus l usure m canique et un endommagement externe par suit...

Page 25: ...irement anormale ainsi que pour les dommages cons cutifs en d coulant tout comme pour les b n fices non r alis s 3 Le fabricant et son repr sentant d clinent toute responsabilit pour les dommages cons...

Page 26: ...laser les yeux sont tout de m me prot g s par le r flexe de fermeture des paupi res Les pictogrammes de danger de la classe 2 sont bien visibles sur le niveau Laser 2 IEC 60825 1 2014 P 1 mW 635 670 n...

Page 27: ...27 FR...

Page 28: ...5 Baunatal Tel 49 561 49 21 45 Fax 49 561 49 72 34 info geo fennel de www geo fennel de Technische nderungen vorbehalten All instruments subject to technical changes Sous r serve de modifications tech...