background image

8

   

Functie Deconectare

 

 1)  

Indicatia lampii 

7 / X-

axa

 2)  

Indicatia lampii 

 8 / Y-

axa

 
   

Calibrare

doar pentru persoane

   

autorizate.

 1)   Indication lamp 7 / X-axis
 2)   Indication lamp 8 / Y-axis

   Calibrator: For authorized  
   dealers only.

7

8

   Sleep-Function

   In order to save energy the laser beam and  
   rotation can be switched off by pressing 

 

   “POWER” on the remote control. To resume, 

 

   the laser beam and rotation can be started by 

 

   pressing “POWER” once again.
 

Important:

 It is not possible to switch the 

 

   unit on/off completely with the remote con-

 

   trol.

În scopul de a economisi energie 

þ

i a razei laser 

poate fi oprit prin ap

ã

sarea "POWER" de pe 

telecomand

ã

Pentru a relua, raza laser 

þ

i rota

þ

ia poate fi 

activat prin ap

ã

sarea "POWER" înc

ã

 o dat

ã

Important: Nu este posibil pentru a comuta 
unitate de on / off complet cu telecomanda.

Summary of Contents for FL 100 HA

Page 1: ...Manual Utilizare Users manual Nivela Laser Orizontala Autonivelanta Fully Automatic Horizontal Laser Level FL 100 HA...

Page 2: ...ttery with charger battery com partment for alkaline batteries remote con trol for slope setting container users manual FEATURES 1 ON OFF Power 2 ON OFF indication lamp 3 Receiving window remote contr...

Page 3: ...quipped with TILT alarm function You can set slopes up to 5 9 in X and Y axis The housing is dust and rain resistant TECHINCAL DATA Self levelling range 5 Accuracy 1 mm 10 m Working range with FR 45 6...

Page 4: ...ed Whilst use of alkaline batteries the recharging function is disabled Battery housing for alkaline batteries Pot fi folosite atat baterii alkaline 4 x C cat si acumulatori NiMH din pachetul de livra...

Page 5: ...100HA offers the additional functions of TILT and SLOPE To operate these functions remove transparent cover on the base of the unit on the opposite side to the battery compartment Asezati pe o suprafa...

Page 6: ...LARM NCLINARE FL100HA este echipat cu func ie alarm NCLINARE Aproximativ 2 minute dup autonivelare procedura este finalizat func ia se va activa automat n cazul n care nivelul este tulburat o sum mare...

Page 7: ...5 POWER SLOPE FUNCTION This mode can only be operated by using the remote control Press 1 x X Y Indication lamp 7 shows that X axis can be tilted with buttons up down Press 2 x X Y Indication lamp 8...

Page 8: ...witched off by pressing POWER on the remote control To resume the laser beam and rotation can be started by pressing POWER once again Important It is not possible to switch the unit on off completely...

Page 9: ...OFF switch 6 Loudspeaker 7 Battery compartment back side 8 Sound on off 9 Accuracy fine normal coarse 10 Light on off 11 Magnets 2 12 1 4 mounting hole for clamp back side Livrare Receptor FR 45 Bater...

Page 10: ...Accuracy normal 4 mm Symbol on display Accuracy fine 2 mm Symbol on display INSTALAREA BATERIEI INSTALLATION OF BATTERIES Open battery compartment cover 7 Put in 1 x 9 V AA battery according to insta...

Page 11: ...me Conectare la Rigla de Nivelare CLAMP FOR LEVELLING STAFF If required FR 45 can be attached to laser poles or any other equipment by means of the clamp supplied with Muta i receptorul FR 45 n sus i...

Page 12: ...ur H henkontrolle bei Beto nierarbeiten Empf nger wird am Vierkantrohr befestigt To attach the laser receiver for checking heights during concrete works H he Height 1 5 m O des Tellers O of disc 38 cm...

Page 13: ...remove warning labels or safety instructions Keep instrument away from children Do not use instrument in explosive environ ment V rug m s manevrati instrumentele de m surare cu grij Cur ati l cu o c...

Page 14: ...otection is normally secured by aver sion responses and the blink reflex Motivele specifice pentru m surarea eronat a rezultatelor ob inute M sur torile prin ferestre din sticl sau din material plasti...

Page 15: ...eakage of the battery bending or dropping the unit are presumed to be defects resulting from misuse or abuse Aceasta nu poate fi exclus complet faptul c acest instrument va deranja alte instrumente de...

Page 16: ...entatives assumes no responsibility for damage caused by wrong movement or action due to connec ting with other products 10 2007 Technische nderungen vorbehalten All instruments subject to technical c...