background image

5

     

PANOU CONTROL

   1)  Tasta Pornit/Oprit
   2)  

Viteza de rotatie

   3)  

Mod scanare

   4)  

Mod inclinare

   5)  TILT-

mod

   6)  

Autonivelare

   A- 

Indicatorul procedurii de calibrare

 

   

Nu este mentionat in manual, fiind doar pentru 

 

   

dealerii autorizati.

 

   

   Comutare Pornit/Oprit  unitate

   

Apasati

  “1” 

pentru pornire unitate

 FL 250VA-N 

 

   

Apasati 

 “1”

 din nou pentru inchidere unitate

 

   

 

 

 

 
 

 

 

 

   CONTROL PANEL

   1)   ON/OFF button 
   2)   Rotatin speed
   3)   Scanning mode
   4)   Slope mode
   5)  TILT mode
   6)   Self-levelling

   A- Indicator lamps calibration procedure  
   Not mentioned in this manual. For autho-

 

   rized dealers only.

   SWITCHING UNIT ON/OFF

   Press button “1” to switch the unit on.
   Press button “1” again to switch the unit 

 

   off.

   After switching on the unit flashing laser 

 

   diode indicates that automatic self-levelling 

 

   procedure is working. Self-levelling procedure   
   may take up to 30 seconds. Laser starts ro-

 

   tating when self-levelled. If not the laser was 

 

   set up out of self-levelling range (indicating 

 

   lamp above button 5 is flashing). In this case 

 

   please set up instrument on more even sur-  
   face. 

   If power indicator lamp at control panel is 

 

   blinking during use of instrument the batte-

 

   ries have to be recharged/alkaline batteries   
   exchanged.

 

 

 

 

Dup

ã

 pornire, pe unitate clipe

þ

te dioda laser 

indicand faptul c

ã

 se auto-niveleaza automat 

Procedura este de lucru. Procedura de auto-
nivelare poate dura pân

ã

 la 30 de secunde. 

Laserul începe s

ã

 se roteasc

ã

 atunci când este 

auto-nivelat. Dac

ã

 nu, laser a fost asezat 

dincolo de gama de auto-nivelare (indicând 
lampa deasupra butonului 5 intermitent). În 
acest caz, va rugam sa înfiin

þ

at instrumentul pe 

o suprafa

þ

ã

 mai dreapta.

Dac

ã

 lamp

ã

 indicatoare de putere de la panoul 

de control clipe

þ

te, în timpul utiliz

ã

rii 

instrumentului, bateriile trebui sa fi reînc

ã

rcate / 

baterii alcaline schimbate.

Summary of Contents for FL 250VA-N

Page 1: ...Manual Utilizare Users manual Nivele laser autonivelanta orizontala si verticala Fully Automatic Horizontal and Vertical Laser Level FL 250VA N...

Page 2: ...baterii 7 Bula circulara 8 2 suruburi reglaj pentru utilizare in pozitie verticala 9 Picior fixare podea KIT CONSISTS OF Rotating Laser Level FL 250VA N receiver FR 45 with clamp for levelling staff...

Page 3: ...NiMH Power supply 48h 4 x C alkal ine Temperature range 20 C 50 C Laser diode Laser class 635 nm 2 Dust Water protection IP 65 depending on room illumination FUNCTII SI CARACTERISTICI FUNCTIONS AND F...

Page 4: ...line batteries the recharging function is disabled ACUMULATORII SI INCARCATORUL Pot fi utilizate atat kit ul de acumulatori NiMH cat si baterii alcaline 4x C NiMH pachet Nivela FL 250VA N vine cu pach...

Page 5: ...velling procedure may take up to 30 seconds Laser starts ro tating when self levelled If not the laser was set up out of self levelling range indicating lamp above button 5 is flashing In this case pl...

Page 6: ...lockwise clock wise To quit scanning mode press button 2 SLOPE MODE Slopes can be set up to 5 in X and Y direction Press button to enter the slope mode To change between X and Y axis press but ton sho...

Page 7: ...oo With the help of the circular bubble the instrument can be set up as accurately as possible Doing so you can use the maximum range for slope setting Dac nivela FL 250VA N este deranjata instrumentu...

Page 8: ...slope is possible in Y axis only in order to avoid mistakes After slope had been set unit will not start self levelling procedure after unit has swit ched off and on again Set up FL 250VA N in horizo...

Page 9: ...r 7 Battery compartment back side 8 Sound on off 9 Accuracy fine normal coarse 10 Light on off 11 Magnets 2 12 1 4 mounting hole for clamp back side KIT LIVRARE Receptor FR 45 Baterie clema prindere p...

Page 10: ...chosen by pressing button 9 Accuracy coarse 10 mm Symbol on display without symbol Accuracy normal 4 mm Symbol on display Accuracy fine 2 mm Symbol on display INSTALAREA BATERIILOR INSTALLATION OF BAT...

Page 11: ...Move receiver FR 45 up and down carefully to detect the laser beam A Move the receiver down Acoustic signal ultra short requent beep B Move the receiver up Acoustic signal short requent beep C On leve...

Page 12: ...ocal dealer Do not remove warning labels or safety instructions Keep instrument away from children Do not use instrument in explosive environ ment V rug m s manuiti instrumente de masurare cu grij Cur...

Page 13: ...allowed to use unit without further safe ty precautions Eye protection is normally secured by aver sion responses and the blink reflex Motivele specifice pentru care rezultatele masurate pot fi eronat...

Page 14: ...his product if it has been misused abused or altered Without limiting the foregoing leakage of the battery bending or dropping the unit are presumed to be defects resulting from misuse or abuse Nu poa...

Page 15: ...age caused by wrong movement or action due to connec ting with other products 10 2007 Utilizatorul acestui produs este de a teptat s urmeze instruc iunile date n manualul de utilizare De i toate instr...

Reviews: