Page 2: ...instrument 2 Accuracy calibration 2 1 Setting the reference 2 2 Sort of the error and calibration methods 3 Adjustment for alarming range 4 Disassembly and assembly of the instrument 4 1 Disassembly...

Page 3: ...The hairspring is broken 3 The 1 controling PCB is broken 1 Jointing the broken connecting line 2 Change the broken hairspring 3 Change 1 circuit board Laser line is dim The laser diode is broken Cha...

Page 4: ...adjacent light ruler to the right front of the adjusting platform the 0 position Of the adjacent light ruler should be consistent with the horizontal reference 0 position 2 2 Sort of the error and cal...

Page 5: ...10mm adjust the adjusting screw in two self check hole on point A on the housing of the instrument figure 3 make the horizontal laser line is coincident with the reference line Figure 3 2 2 1 1 2 If...

Page 6: ...figure 3 When adjust the two screws on point D it need to loosen one screw before tighten another screw until the horizontal laser line is coincident with the reference line The degrees of tightness o...

Page 7: ...one screw before tighten another screw until the horizontal laser line icoincident with the reference line The degrees of tightness of the two screws should be nearly the same finally 2 2 3 2 Calibrat...

Page 8: ...3 13 Then move 3 connecting PC board in horizontal make the alarming pole of 2 alarming PC board 3 13 locate in the centre of the alarming ring then fasten the screws When the incline degree of any di...

Page 9: ...th a cutter 1 1 2 Use a cross screwdriver to turn off 4 pcs cross head plate tapping screw ST2 2x5 1 4 and take off 1 operation PC board G609 1 operation PC board 1 3 3 Pull a little harder to move of...

Page 10: ...1 by a cross srewdriver move off 4 alarming PCB G609 4 alarming PCB 3 4 6 Screw off 1 pc of cross head plate screw M2X10 3 9 by a cross srewdriver move off horizontal laser module green laser module...

Page 11: ...ery cover part 4 9 3 Use electric iron to burn down the leading line of the power supply plug move off the contacting part 4 6 4 Screw off 3 pcs of nut M2 5 4 2 by a cross srewdriver move off 6 pcs of...

Page 12: ...board 6 15 6 1 Lifting bracket 6 2 Locking sheet 2 6 3 Damping bracket 6 4 Cross head plate tapping screw ST2 2X5 5 6 5 Locking ring 5 6 6 Cam 6 7 Cross head plate tapping screw ST2 9X9 5 9 6 8 Magne...

Page 13: ...the Locking ring 6 6 17 saperate turnplate 6 22 2 pcs of gasket 6 18 2 pcs of saddle pad 6 19 lifting bracket 6 1 7 Screw off 4 pcs of cross head plate tapping screw ST2 9X9 5 6 7 move off the base co...

Page 14: ...showed in figure 11 connect the corresponding connecting line to each PCBs accordingly Solder 4 hairsprings to the corresponding place of4 Alarming PC board or G609 4 Alarming PC board 3 4 and 3 Conne...

Page 15: ...that note especially Requirement of assembly a Gelatinize 706 glue water on the jointing as follows The interface between base 4 5 and inserting block 4 13 Lifting bracket 6 1 and press cover 6 21 Fin...