15
Recorded Pressings (User Odometer)
There is an “odometer” that records
pressing cycles done. This can be cleared
and reset to 0 at any time when needed.
The figure scrolls and it’s beginning and
end are separated by a “-” sign.
After entering the user menus (see
top of page 14), Press PRG until REC
displays. Use the arrow keys to reset the
counter to 0. Press PRG to move to the
next menu item.
Pressure Minimum
To reset and redefine “0” for the pressure
bar graph, use this calibration menu. Do
NOT adjust this setting unless you are
sure adjustments are necessary.
Adjust the pressure of the machine so
there is barely any locking pressure
when clamping and locking the press.
Press either Arrow Key. The press now
considers this pressure as “0” on the
Pressure Bar Graph Display.
Press PRG to move to the next menu item.