Page 44/55
© Geobrugg Gruppe, CH-8590 Romanshorn, Switzerland
RXE-1000 / 17
INSTALLATION OF THE SECONDARY MESH
The individual fields are fitted with a diagonal wire mesh 50x50x2.4.
The wire mesh
221
is fixed with double wire ties
222
on the ring net
220
. The wire tie is attached to each ROCCO
ring in any intermediate series. The wire mesh strips overlap each other 10cm.
222
10 cm
220
221
15 cm
50 cm