10
APPENDIX D. SYSTEM WIRING
D.1 CR6 Wiring
CR6
Connections
Internal
MUX 1 Interface
Ribbon Cable
CR6
Power
Cable
Description
U1
Brown
NC
Vibrating Wire +
U2
Red
NC
Vibrating Wire -
U3
Orange
NC
Ther
U4
Yellow
NC
Thermistor -
U5
Gray
NC
MUX Enable 1
C4
White
NC
MUX Clock
12V
Blue
NC
MUX 12 VDC
G
Violet
NC
Ground
AG
Black and Green NC
Analog
Ground
PWR IN 12V NC
Red
CR6
12 VDC
PWR IN G
NC
Black CR6
Power Ground
Table 6 - CR6 Wiring
NOTE:
Ports U1 and U2 are used for Vibrating Wire when the 8600-2 is configured for 32 ea
Vibrating Wire Gauges. U3 and U4 are used when the 8600-2 is configured for 32 ea
Thermistors.
D.2 Charger Port Wiring
Pin
Description
Wire Color
A
Unregulated Charger
Gray
B
Ground
Blue
C
Regulated Charger / External
Battery
Violet
Table 7 - Charger Port Wiring
D.3 Unregulated Charger Wiring
Pin
Description
Wire Color
A
Unregulated Charger
Red (Black Smooth)
B
Ground
Black (Black Rough)
C
No Contact
NC