E.3 Modifying the Datalogger Program
Navigate to the Include (.DLD) file on the end user’s computer C:\Campbellsci\CRBasicEditor.
Optional changes to Scan Interval, Zero Readings, Gauge Factors and Alias names can be made
by opening the Include (.DLD) file with Notepad. Each Datalogger configuration has a unique
Include (.DLD) file.
W
ARNING
:
O
NLY CHANGE VALUES AFTER THE
“=”
SIGN
.
E.3.1 Scan Interval
The number entered in the Scan Interval section determines how often the Datalogger will
read the gauges and store data. The Scan Interval is in seconds.
Figure 13 - Set the Scan Interval
E.3.2 Zero Readings and Gauge Factors
Default values for Zero Readings are 0 and Linear Gauge Factors are 1. The default
settings read in Digits for Vibrating Wire sensors and Volts for MEMS tilt sensors. Zero
Readings and Gauge Factors can be added if the user requires the Datalogger to store
engineering units.
Figure 14 - Set Zero Readings and Gauge Factors