31
F.3.3 Model 8032-27 and Load Cell Wiring
Connect the “common” VW- conductor from the load cell to the 8032-27 by lifting up on
the orange tab located on the opposite side of the six black conductors, inserting the
common conductor fully into the 8032-27 (Figure 34), and then pushing down on the
orange tab until it snaps into place. Refer to Table 16 to identify which conductor carries
the common VW- signal.
Figure 34 - Model 8032-27 Jumper Wire Assembly
10 pin Bendix
PT06A-12-10P
Function 3 Gauge VW Load
Cell, Purple Cable
4 Gauge VW Load
Cell, Purple Cable
6 Gauge VW Load
Cell, Orange Cable
H
Common
White's Black*
Green
Blue
*
White's black and Green wires are switched on Geokon 3 gauge VW load cells prior to serial number 3313.
Table 16 -Common Conductor Chart
Table 17 details the connections between the load cell and 8032-27 with the multiplexer
board.
Multiplexer
Board
Vibrating Wire
with Thermistor
1H
VW Sensor #1
1L
8032-27
2H
Thermistor
2L
Thermistor
S1
Shield Drain Wire
3H
VW Sensor #2
3L
8032-27
4H
-
4L
-
S2
-
5H
VW Sensor #3
5L
8032-27
6H
-
6L
-
S3
-
•
•
•
•
•
•
11H
VW Sensor #6
11L
8032-7
12H
-
12L
-
S6
-
Table 17 - Standard VW Load Cell Wiring When Using 8032-27