34
4.32 “SR1” - Readings will Synchronize with the Hour
(Default) Readings will be synchronized to the top of the hour. All subsequent readings will
occur at the specified scan interval while evenly divisible into the top of the hour.
*SR1
Readings are synchronized to the top of the hour.
*SC5
Scan interval: 5 second(s).
*ST
Logging started.
2009,195,0923,17,3.07,23.93,-9025.767,23.4,1
*2009,195,0923,20,3.07,23.96,-9025.185,23.4,2
*2009,195,0923,25,3.07,24.05,-9025.486,23.4,3
2009,195,0923,30,3.07,24.08,-9025.754,23.4,4
2009,195,0923,35,3.07,24.08,-9025.632,23.4,5
2009,195,0923,40,3.07,24.08,-9025.486,23.4,6
4.33 “RT8” - Set Maximum Number of Readings to 8000
Sets the total number of readings to 8000.
*RT8
8000 readings maximum
*
4.34 “RT16” - Set Maximum Number of Readings to 16000
Sets the total number of readings to 16000.
*RT16
16000 readings maximum
*
4.35 “S” - Display Status
Displays the datalogger status.
*S
MS:3200 OP:1567 UP:1
GT: 1 GZ: 8934.0000 GF: 0.01234 GO: 0.00000
Scan interval: 60 second(s).
Logging started.
Logging will stop at: 10:50:00
Log intervals enabled.
Monitor mode disabled.
*