EXCEL-CPD
1
GENERAL
POINTS FOR THE PURCHASER
The EXCEL stove has been individually designed to add traditional
charm and character
to your home. Providing a highly efficient heat source, the EXCEL has the look and
charm of a 'real' stove coupled with the convenience
of clean burning gas.
The stove is designed to run both off natural or LPG gas however each individual
appliance is only capabl
e
of running off the type of gas specified at the time of purchase.
It is important
to note that once a type of gas has been specified the stove cannot run off
any other t
y
pe. The type of gas which your stove is capabl
e
of burning is stated on the
data information
panel (See Paragraph
3).
Important
Notes
a) These instructions
have been compiled in accordance with BS 5258 Part 13: 1986.
Ensure that the stove corresponds
to the type of gas it is to be used with. This can be
confirmed
by checking the data badge located on the rear face of the appliance.
Prior to installation
it is essential that the chimney should be swept and its condition
and suitability for use with the appliance checked.
Remember
at all times this product
is concerned
with high temperatures,
and
appropriate
care should ahva
y
s be taken
.
Bear in mind that the heat given off by the appliance may affect arti
c
les placed
c
lose to
it. Curtains should not be positioned
above the appliance at a distance less than 12"
(
30 centimetres
)
from the top.
The appliance was not designed to be used as a dryer
.
It is therefore not
recommended
that the appliance is used in such a manner
.
Under no circumstances
should the appliance be operated with the front removed or
the door glass damaged
.
A combustibl
e
shelf may be fitted over the appliance provided that in the case of a
1500101 or l
e
ss deep shelf, there is at l
e
ast 6100101 clearance above the top of the fire
(
measured
from its highest point
).
Please remember that parts of the appliance will get hot during and after use.
If young children, the elderly, or infirm are likely to be near the stove,
ensure a suitable fire guard (BS 6539 or BS 6778) is erected
The appliance is fitted with a thermostatic
switch
(
TTB
)
which senses an
y
excess
temperature
due to a flue blockage. In the event of a partial or total blockage the gas
supply will be automatically
cut
.
Should this occur turn the control knob to the off
position and wait approximately
10 minutes for the switch to automaticall
y
reset.
57766