WARNING
Improperly repaired equipment
Risk of injuries to users and equipment destruction due to lack of repair knowledge.
Precautions:
▶
Only authorised GeoMax Service Centres are entitled to repair these products.
1.6
Laser Classification
1.6.1
General
The following chapters provide instructions and training information about laser safety according
to international standard IEC 60825-1 (2014-05) and technical report IEC TR 60825-14
(2004-02). The information enables the person responsible for the product and the person who
actually uses the equipment, to anticipate and avoid operational hazards.
☞
According to IEC TR 60825-14 (2004-02), products classified as laser class 1,
class 2 and class 3R do not require:
•
laser safety officer involvement,
•
protective clothes and eyewear,
•
special warning signs in the laser working area
if used and operated as defined in this User Manual due to the low eye hazard level.
☞
National laws and local regulations could impose more stringent instructions for the
safe use of lasers than IEC 60825-1 (2014-05) and IEC TR 60825-14 (2004-02).
1.6.2
Distance, Measurements with Reflectors
The EDM module built into the product produces a visible laser beam which emerges from the
telescope objective.
The laser product described in this section is classified as laser class 1 in accordance with:
•
IEC 60825-1 (2014-05): “Safety of laser products”
These products are safe under reasonably foreseeable conditions of operation and are not harm-
ful to the eyes provided that the products are used and maintained in accordance with this User
Manual.
Description
Value
Wavelength
658 nm
Pulse duration
800 ps
Pulse repetition frequency (PRF)
100 MHz
Maximum average radiant power
0.33 mW
Beam divergance
1.5 mrad x 3 mrad
General
General
10
Safety Directions