ZDL700 |
*
7
User Interface
I
2. Intermediate
Sight
ON / OFF
Enable / disable Intermediate Sight in BIF line levelling.
3. Input PtID
Input user point ID.
4. Input BM
Input Reference Benchmark elevation.
5. Data Manager
View Data
Viewing recorded data / deleting of a recorded data by pressing ENTER key.
Download Data (GSI / ASCII)
Transferring of recorded data to PC via RS232, in GSI-8 or ASCII format.
Delete All Data
Deleting of all recorded data in the on-board / internal memory.
6. Recording
Memory
Measurement recorded to on-board / internal memory.
)
In line levelling application, recording mode has to be set prior to first
backsight measurement.
Off
Measurement not stored.
Ext
Measurement recorded to external device in GSI-8 format via RS232 cable.
7. Adjustment
Adjustment program.
8. Inverse Staff
ON [Inverted], OFF [Upright], AUTO
[Auto recognition of staff orientation]
Recognition mode setting of staff orientation.
Menus
Selections (sub-selections)
Descriptions