background image

 
 
 
 
 
 
 

 

Page 5 

 

 

1.  Connect the 

ZEB Horizon

 scanner to the datalogger using the main cable and power 

on the system as normal. 

2.  Connect the camera to a PC as outlined in the 

ZEB Vision User Guide

3. 

Open

  -> 

GeoSLAM Control Tool 

(Figure 2)

 

Figure 2. GeoSLAM Control Tool. 

 

4. 

Select

 -> 

Connect, 

to open the Control Selection (Figure 3) 

 

 

Figure 3.  Control Selection. 

 

5. 

Select

 -> 

ZEB Vision

6. 

Select 

-> 

OK

, to continue. 

7. 

Input

 -> 

169.254.0.206

, at the IP address popup to detect the camera (Figure 4)

 

Summary of Contents for ZEB Horizon

Page 1: ...Firmware Update Guide Instructions for firmware upgrades ...

Page 2: ...sed in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area may cause interference SOFTWARE IS PROVIDED AS IS To the maximum extent permitted by law the manufacturer GeoSLAM Ltd and its suppliers disclaim all warranties either express or implied including but not limited to implied warranties of merchantabil...

Page 3: ...ures Figure 1 Updating the camera calibration file 3 Figure 2 GeoSLAM Control Tool 5 Figure 3 Control Selection 5 Figure 4 Enter the camera IP address 6 Figure 5 Camera successfully connected 6 Figure 6 Software update 7 Figure 7 Firmware update confirmation 8 Figure 8 GeoSLAM Control Tool 10 Figure 9 Control Selection 10 Figure 10 Datalogger successfully connected 11 Figure 11 SHB Software update...

Page 4: ...the firmware using the GeoSLAM Control Tool The current and new firmware versions are document in Table 1 Current New ZEB Vision Firmware 1 2 0 2 1 0 ZEB Horizon SHB Firmware 1 6 2 2 0 GeoSLAM Control Tool 3 2 0 3 3 0 Table 1 Current and new firmware versions covered by this document When updating the ZEB Vision to the version 2 1 users must also update the ZEB Horizon SHB firmware to version 2 2 ...

Page 5: ...dures are in Section 3 of this guide Calibration File Location The camera calibration file camera_cal json is now stored in a protected directory on the camera to avoid accidental deletion A copy of the calibration file is now automatically stored in the image folder If users need to update the calibration file then the file must be uploaded to the protected directory using GeoSLAM Control Tool v3...

Page 6: ... The ZEB Vision camera now gives more feedback during capture please see the LED table below Camera Status LED Description Start Up ZEB Vision connected successfully illuminates 3 seconds after power on ZEB Vision not connected successfully illuminates 8 seconds after power on Capture Flashing at 1 second intervals indicates images are stored Memory Low Error with Capture ...

Page 7: ...mware update SHB_2_2_Gen 1 Datalogger SHB_2_2_Gen 2 Datalogger DataloggerTools 3 3 0 zip ZEB_Vision_2_1_0 7z Firmware update files for 1st generation data loggers Firmware update files for 2nd generation data loggers Control Tool software to apply the firmware updates Firmware update file for Vision camera Table 2 Update package contents Extract the Control Tool software to a directory on the PC N...

Page 8: ...e camera to a PC as outlined in the ZEB Vision User Guide 3 Open GeoSLAM Control Tool Figure 2 Figure 2 GeoSLAM Control Tool 4 Select Connect to open the Control Selection Figure 3 Figure 3 Control Selection 5 Select ZEB Vision 6 Select OK to continue 7 Input 169 254 0 206 at the IP address popup to detect the camera Figure 4 ...

Page 9: ...Page 6 Figure 4 Enter the camera IP address 8 Select OK to continue The camera should now be connected Figure 5 Figure 5 Camera successfully connected 10 Select Software Update Software Update Figure 6 ...

Page 10: ...7 Figure 6 Software update 11 Select Yes at the dialog to select to update the firmware 12 Browse user defined location of the update file a Select OK to continue 13 Select Yes to confirm the update Figure 7 ...

Page 11: ...ated to firmware version 2 2 or later to function with Vision firmware 2 1 Once upgraded the ZEB Horizon will now be ready for use with either a ZEB Vision or ZEB Cam When updating this firmware please ensure the scanner is connected to the datalogger before the system is powered on Please follow the steps relating to the appropriate iteration your ZEB Horizon datalogger Information on how to dist...

Page 12: ... the data LED light has switched off remove the USB and power off the datalogger 7 Power on the system as normal 8 After flashing blue the datalogger status LED will flash red and the scanner LED will illuminate orange during the update Once complete the system automatically powers off 9 Wait 10 seconds before powering on the system again The system should now complete the initialisation process a...

Page 13: ...nnect to open the Control Selection Figure 9 Figure 9 Control Selection 5 Select ZEB Datalogger 6 Select OK to continue 7 Select at the IP address popup to detect the datalogger 8 Select OK to continue The datalogger should now be connected Figure 10 ...

Page 14: ...gger successfully connected 9 Select Software Update SHB software Figure 11 Figure 11 SHB Software update 10 Browse user defined location of the update file b Select OK to continue 11 Select Yes to confirm the update Figure 12 ...

Page 15: ...on 12 Select OK to continue at the information dialog Figure 13 Figure 13 Update Information dialog 13 After the update has finished the Datalogger will shutdown and the connection to the Datalogger Control Tool will be lost 14 Restart the system ...

Reviews: