background image

This action is used for further calibration of the internal inertial navigation
system. If this action is not performed, the accuracy of the data collected
during the flight will decrease.
9. After scanning, disconnect the power of the device, take out the data from
the micro SD cards, and perform the calculation operation

by Shuttle and

gAirhawk software

on the computer.

GS-100M uses one micro SD cards (TF card), respectively used to store POS
and LIDAR data.
Each flight, the system will automatically create a folder named as the current
point in time, and store all the data collected in this folder directory.
Regarding the micro SD card, please use it according to the following terms:
[1] Please select a micro SD memory card above C10 U1 level.
[2] Approximately 5.5GB of data is generated every 10 minutes when runs
LiDAR system (in the triple echo mode). Please make sure that the remaining
space in the micro SD card is sufficient for next flights.
[3] When the microSD card is connected to the computer, the computer
system will pop up a dialog box prompting that the storage device needs to be
scanned. At this time, be sure to select "Scan and Repair", otherwise the data
in the micro SD card may not be read and written normally.

GS-100M contains G64GB eMMC (The real capacity is 54 GB) Flash memory

GS-100M Data Storage Instruction

Summary of Contents for gAirHawk

Page 1: ...gAirHawk GS 100M UAV LiDAR Scanning System Operation Manual Wuhan Geosun Navigation Technology Co Ltd...

Page 2: ...the acquisition of 3D spatial information in surveying electricity forestry agriculture land planning Interface type Interface model Function GNSS Antenna port TNC connector Connected extenal GNSS an...

Page 3: ...GS 100M Side View as Above Figure GS 100M Side View as Above figure 1 Micro SD slot 1 Type C interface 3 interface and 4 LED Indicators...

Page 4: ...for the system to initialize and lock the star then wait for the led indicator lights in normal The power indicator is on the GNSS indicator flashes one time in 1 intervals and the LIDAR indicator fla...

Page 5: ...ll the data collected in this folder directory Regarding the micro SD card please use it according to the following terms 1 Please select a micro SD memory card above C10 U1 level 2 Approximately 5 5G...

Page 6: ...type of cable cannot be used Connect the lidar device to the user s computer the lidar power cable does not need to be connected The computer will automatically recognize the lidar as a mobile storag...

Page 7: ...data are saved normally Steady light for more than 60s system is abnormality please refer to troubleshoot instructions TRIG Indicator Light off no trigger signal output Flash According to user config...

Page 8: ...gured to be at a 2 second isochronous interval low level trigger and pulse width 15ms in default If you need to configure other trigger methods please contact our technical support staff The technical...

Page 9: ...icator is off for a long time The lidar data will be read and stored only after the system completes the locking stars Please make sure the system locks the star normally If the LIDAR indicator is sti...

Reviews: