for backing up the collected data to prevent data loss due to accidental
damage of the micro SD card.
If users need to read the data in eMMC Flash, please use USB type-C data
cable.
(Please make sure that the cable has a data transmission function. Some
cables may only have a power function. This type of cable cannot be used.)
Connect the lidar device to the user's computer (the lidar power cable does not
need to be connected). The computer will automatically recognize the lidar as
a mobile storage device, and then can perform data operations.
When each flight, it will automatically determine the remaining free space in
the eMMC flash memory. If the remaining space is less than 20GB, the system
will automatically delete the oldest data files until the remaining space is
greater than 20GB.

Summary of Contents for gAirHawk

Page 1: ...gAirHawk GS 100M UAV LiDAR Scanning System Operation Manual Wuhan Geosun Navigation Technology Co Ltd...

Page 2: ...the acquisition of 3D spatial information in surveying electricity forestry agriculture land planning Interface type Interface model Function GNSS Antenna port TNC connector Connected extenal GNSS an...

Page 3: ...GS 100M Side View as Above Figure GS 100M Side View as Above figure 1 Micro SD slot 1 Type C interface 3 interface and 4 LED Indicators...

Page 4: ...for the system to initialize and lock the star then wait for the led indicator lights in normal The power indicator is on the GNSS indicator flashes one time in 1 intervals and the LIDAR indicator fla...

Page 5: ...ll the data collected in this folder directory Regarding the micro SD card please use it according to the following terms 1 Please select a micro SD memory card above C10 U1 level 2 Approximately 5 5G...

Page 6: ...type of cable cannot be used Connect the lidar device to the user s computer the lidar power cable does not need to be connected The computer will automatically recognize the lidar as a mobile storag...

Page 7: ...data are saved normally Steady light for more than 60s system is abnormality please refer to troubleshoot instructions TRIG Indicator Light off no trigger signal output Flash According to user config...

Page 8: ...gured to be at a 2 second isochronous interval low level trigger and pulse width 15ms in default If you need to configure other trigger methods please contact our technical support staff The technical...

Page 9: ...icator is off for a long time The lidar data will be read and stored only after the system completes the locking stars Please make sure the system locks the star normally If the LIDAR indicator is sti...

Reviews: